Fixation of olecranon fractures and osteotomies using compression screws: a simple solution to a common problem. A study of cases.
نویسندگان
چکیده
Olecranon fractures are common skeletal injuries accounting for approximately 10% of upper extremity fractures in adults. Simple non-comminuted fractures are traditionally fixed using the tension band wiring technique. This technique, however, has several complications, most commonly prominence of the metalwork frequently requiring surgery for removal. We describe a retrospective review of a new method of fixation for these fractures using partially threaded screws in an attempt to avoid these complications. We used two 3.5 and/or 4 mm partially threaded screws to fix seven simple olecranon fractures and two olecranon osteotomies. Notes and clinic letters of all nine patients were reviewed for demographic data, operation details and complications. Radiographs were reviewed at final clinical follow-up. The Mayo Elbow Performance Score was completed during a telephone consultation. One patient injured her elbow postoperatively, which resulted in fragmentation of the proximal segment and loss of fixation. In one patient the tip of the screws broke after a fall but this did not result in loss of fixation. There were no problems with metalwork prominence or skin irritation in any of the patients. Two patients had low scores due to loss of fixation, and severely comminuted supracondylar fracture of the humerus. Six patients had good scores. We believe that use of AO compression screws is a valid method for the fixation of simple fractures of the olecranon. It is a safe technique and has several advantages over tension band fixation. There is minimal tissue dissection and operating time is decreased. There is minimal risk of metalwork prominence as screws obtain good purchase in the anterior cortex of ulna. Good interfragmentary compression is achieved as screws are perpendicular to the fracture line and two screws provide good rotational stability. Protection of fixation for 1014 days does not result in significant loss of range of motion. Further clinical and biomechanical studies are suggested to compare this technique with other methods of fixation of olecranon fractures.
منابع مشابه
A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملClinical evaluation of locking compression plate fixation for comminuted olecranon fractures.
BACKGROUND In patients managed with plate fixation for the treatment of an olecranon fracture, the placement of an axial intramedullary screw may obstruct the placement of bicortical screws in the ulnar shaft. To overcome this problem, unicortical screws can be applied with use of a contoured locking compression plate. The present study was designed to assess the effectiveness of this fixation ...
متن کاملScaphoid Fractures: A Comparison of Two Surgical Methods for Internal Fixation Using Either Herbert Screws or Multiple Pins
Background and Aims: Scaphoid fractures are the most common fractures of the wrist. This study compared the outcomes of two surgical internal fixation techniques, using either Herbert screws (HS group) or multiple pins (MP group), in the treatment of scaphoid fractures. Methods: This cross-sectional study was performed on 41 patients (23 in HS and 18 in MP groups) with unilateral scaphoid fract...
متن کاملBilateral Simultaneous Femoral Neck and Shafts Fractures – A Case Report
Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression pl...
متن کاملبررسی نتایج درمان جراحی شکستگیهای داخل مفصلی دیستال استخوان بازو (بررسی 46 بیمار)
Background and Aim: Intra-articular fractures of distal humerus in adults present a controversial challenge for orthopedic surgeons. Minor irregularities of the joint surface of the elbow usually cause some loss of function. This can usually be minimized by early, accurate open reduction with sufficiently rigid fixation to permit immediate motion. The posterior approach combined with Olecra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ortopedia, traumatologia, rehabilitacja
دوره 15 4 شماره
صفحات -
تاریخ انتشار 2013