Histological, histomorphometric and microtomographic analyses of retrieval hip resurfacing arthroplasty failed at different times

نویسندگان

  • Francesca Salamanna
  • Milena Fini
  • Annapaola Parrilli
  • Matteo Cadossi
  • Nicolò Nicoli Aldini
  • Gianluca Giavaresi
  • Deianira Luciani
  • Sandro Giannini
چکیده

BACKGROUND Metal-on-metal hip resurfacing arthroplasty (HR) has been gaining popularity especially for young and active patients. Although different series report good mid-term results, the long-term outcome and failure mechanisms are still concerning. In this consecutive revision case series, 9 retrieved specimens of a failed Birmingham Hip Resurfacing (BHR) were divided according to the time to fracture: 3 specimens failed at less than 6 months (Group 1), 3 failed between 6 months and 3 years (Group 2) and 3 failed later than 3 years (Group 3). The objective of the study was to examine by a specific quantitative histomorphometry and microtomography (micro-CT) method the characteristics of bone quality and its microarchitecture in retrieved metal-on-metal HR. METHODS A series of 948 BHR were performed between 2001 and 2009. Among these implants 10 failures occurred and nine of these underwent revision surgery and were examined by histomorphometry and micro-CT. RESULTS Histomorphometry showed a significant increase in trabecular separation (Tb.Sp) in Group 3 in comparison with Group 1 (113%, p < 0.05). In the top region, micro-CT showed that Groups 2 and 3 presented significant lower bone volume (Group 2: 61%, p < 0.005; Group 3: 1%, p < 0.05), trabecular number (Group 2: 53%, p < 0.005; Group 3: 40%, p < 0.05), and higher Tb.Sp (Group: 71%,p < 0.05) when compared to Group 1. Additionally, histomorphometry showed that the top regions in Group 1 had a significantly lower mean percentage of empty osteocyte lacunae than the top regions in both Group 2 and 3 (p < 0.05). CONCLUSIONS This study showed that the morphometric parameters considered are crucial for a good understanding of mechanical properties of HR and may be of significant importance in the pathogenesis of HR failure particularly in the development of late fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing.

This study compared component wear rates and pre-revision blood metal ions levels in two groups of failed metal-on-metal hip arthroplasties: hip resurfacing and modular total hip replacement (THR). There was no significant difference in the median rate of linear wear between the groups for both acetabular (p = 0.4633) and femoral (p = 0.0872) components. There was also no significant difference...

متن کامل

Lessons learnt from early failure of a patient trial with a polymer-on-polymer resurfacing hip arthroplasty

Background and purpose - Hip resurfacing (HR) is a treatment option promoted for hip arthritis in young and active patients. However, adverse reactions to metal are a concern and the search for non-metallic bearing options proceeds. We present the first clinical study performed in patients using a newly developed hydrophilic polymer-on-polymer hip resurfacing device. Patients and methods - Afte...

متن کامل

Osteonecrosis in retrieved femoral heads after failed resurfacing arthroplasty of the hip.

We present the histological findings of bone retrieved from beneath the femoral components of failed metal-on-metal hip resurfacing arthroplasties. Of a total of 377 patients who underwent resurfacing arthroplasty, 13 required revision; for fracture of the femoral neck in eight, loosening of a component in three and for other reasons in two. None of these cases had shown histological evidence o...

متن کامل

Revision of Failed Hip Resurfacing and Large Metal-on-Metal Total Hip Arthroplasty Using Dual-Mobility Components.

Revision of metal-on-metal (MoM) total hip arthroplasty (THA) or hip resurfacing is associated with high complication rates. The authors propose dual-mobility components as a surgical option and present short- to mid-term results of MoM hips revised with dual-mobility components. Eighteen consecutive hips that underwent revision of MoM THA or hip resurfacing using dual-mobility components were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013