A Comparison of Fast Factorised Back-projection and Wavenumber Algorithms for Sas Image Reconstruction

نویسندگان

  • A. J. Hunter
  • M. P. Hayes
  • P. T. Gough
چکیده

Abstract The Fast Factorised Back-Projection (FFBP) algorithm has received considerable attention recently for SAS image reconstruction. The FFBP algorithm provides a means of trading image quality and/or resolution for a reduction in computational cost over standard Back-Projection. In this paper we describe FFBP for SAS image reconstruction and compare it to the Wavenumber algorithm in terms of computational cost and image quality. The FFBP algorithm significantly out-performs standard Back-Projection. However, we have found that FFBP is out-performed by the Wavenumber algorithm. Further investigation is required to determine which algorithm is more desirable for motion compensation and multiple-receiver reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

A model based, anatomy dependent method for ultra-fast creation of primary SPECT projections

  Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the eff...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003