Two-axis MEMS Scanning Catheter for Ultrahigh Resolution Three-dimensional and En Face Imaging.
نویسندگان
چکیده
Ultrahigh resolution two and three-dimensional optical coherence tomography (OCT) imaging was performed using a miniaturized, two-axis scanning catheter based upon microelectromechanical systems (MEMS) mirror technology. The catheter incorporated a custom-designed and fabricated, 1-mm diameter MEMS mirror driven by angular vertical comb (AVC) actuators on both an inner mirror axis and an outer, orthogonal gimbal axis. Using a differential drive scheme, a linearized position response over +/- 6 degrees mechanical angle was achieved. The flexible, fiber-optic catheter device measured < 5 mm in outer diameter with a rigid length of ~ 2.5 cm at the distal end. In vivo and ex vivo images are presented with < 4 microm axial and ~ 12 microm transverse resolution in tissue.
منابع مشابه
High-speed line-field confocal holographic microscope for quantitative phase imaging.
We present a high-speed and phase-sensitive reflectance line-scanning confocal holographic microscope (LCHM). We achieved rapid confocal imaging using a fast line-scan CCD camera and quantitative phase imaging using off-axis digital holography (DH) on a 1D, line-by-line basis in our prototype experiment. Using a 20 kHz line scan rate, we achieved a frame rate of 20 Hz for 512x512 pixels en-face...
متن کاملTwo-axis magnetically-driven MEMS scanning catheter for endoscopic high-speed optical coherence tomography.
A two-axis scanning catheter was developed for 3D endoscopic imaging with spectral domain optical coherence tomography (SD-OCT). The catheter incorporates a micro-mirror scanner implemented with microelectromechanical systems (MEMS) technology: the micro-mirror is mounted on a two-axis gimbal comprised of folded flexure hinges and is actuated by magnetic field. The scanner can run either static...
متن کاملUltrahigh-speed optical coherence tomography for three-dimensional and en face imaging of the retina and optic nerve head.
PURPOSE To demonstrate ultrahigh-speed optical coherence tomography (OCT) imaging of the retina and optic nerve head at 249,000 axial scans per second and a wavelength of 1060 nm. To investigate methods for visualization of the retina, choroid, and optic nerve using high-density sampling enabled by improved imaging speed. METHODS A swept-source OCT retinal imaging system operating at a speed ...
متن کاملSingle fiber confocal microscope with a two-axis gimbaled MEMS scanner for cellular imaging.
We present a single fiber reflectance confocal microscope with a two dimensional MEMS gimbaled scanner. Achieved lateral and axial resolutions are 0.82 mum and 13 mum, respectively. The field of view is 140 x 100 mum at 8 frames/second. Images and videos of cell phantoms and tissue are presented with sub-cellular resolution.
متن کاملUltrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology
We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, whic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 15 5 شماره
صفحات -
تاریخ انتشار 2007