Environmental Radiation Surveillance and Area Monitoring System of Accelerators

نویسندگان

  • Rendao Wang
  • Nan Chen
چکیده

We have built four stations of environmental radiation surveillance of gamma and neutron to monitor the leaked radiations and the exhaust airborne radiot · . t 1) ac lVl y arolmd HIRFL. The loe;ic diaGram 9f the HIRFL' s four stations is shown in Fig.1. Every station consists of an~ detector, whioh has been made by using a counter tube composed of BF3 with mcderator of polyethylene containing boron, a gamma detector made by using a cylinder ionization chamber filled with argon, and a simple-plate computer which has been used as a data-collector to read the data from the counter to registers once ten minutes. The data in the registers will be sent to a central microcomputer once a week, in which they will be printed out

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Malaria Surveillance System in the Islamic Republic of Iran: History, Structures, and Achievements

Background and Objectives: Iran started malaria elimination campaigns many years ago. The purpose of this study was to review the malaria surveillance system in Iran.   Methods: The data of this study were obtained from the surveillance system of the Center for Communicable Disease Control, a review of records, documents, books and published articles, and also interviews with process owners a...

متن کامل

The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...

متن کامل

Unexpected dose and the biological effect of neutron contamination in linear accelerators

Employing High-energy photons in medical linear accelerators can lead to neutron contamination. The relative biological effect of neutrons is 20 times higher than photons. Consequently, its damage to the biological tissue is much higher and unobtrusive. In this study, we calculated neutron equivalent dose in a medical linear accelerator by the FLUKA Monte Carlo code system. The results show tha...

متن کامل

New Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators

Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...

متن کامل

Neutron spectrometry with Bonner Spheres for area monitoring in particle accelerators.

Selecting the instruments to determine the operational quantities in the neutron fields produced by particle accelerators involves a combination of aspects, which is peculiar to these environments: the energy distribution of the neutron field, the continuous or pulsed time structure of the beam, the presence of other radiations to which the neutron instruments could have significant response an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014