Influence of Pelvic Tilt on Polyethylene Wear after Total Hip Arthroplasty

نویسندگان

  • Taro Tezuka
  • Yutaka Inaba
  • Naomi Kobayashi
  • Hiroyuki Ike
  • So Kubota
  • Masaki Kawamura
  • Tomoyuki Saito
چکیده

We aimed to evaluate the effects of pelvic tilt on polyethylene wear after total hip arthroplasty (THA). A total of 105 joints treated with primary THA were included; conventional polyethylene (CPE) liners were used in 43 hips and highly cross-linked polyethylene (HXLPE) liners were used in the remaining 62 hips. The pelvis was tilted 6° posteriorly in the standing position as compared to the supine position, which resulted in significant increases of 1.7° and 2.8° in cup inclination in the CPE and HXLPE groups, respectively. Moreover, the change in pelvic tilt resulted in significant increases of 3.6° and 4.9° in cup anteversion in the CPE and HXLPE groups, respectively. For the CPE group, multiple regression analysis showed a significant association between the angle of pelvic tilt (PTA) and cup inclination and the polyethylene wear ratio. The adjusted R (2) of the regression model was larger for measures obtained in the standing position as compared to the supine position. For the HXLPE group, there was no significant relationship between radiographic parameters and polyethylene wear. Close observation of polyethylene wear is recommended for patients with severe posterior pelvic tilt who have undergone THA with conventional polyethylene.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis

Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiogr...

متن کامل

Reactive pelvic cyst following total hip arthroplasty. A case report.

A 77-year-old woman presented with an intrapelvic cyst which had developed secondary to polyethylene wear of the socket after total hip arthroplasty. This reactive cyst surrounded polymethylmethacrylate cement fragments due to excessive penetration in the pelvis during the initial procedure 20 years previously. This pelvic mass was responsible for gynaecologic symptoms. The cyst was resected in...

متن کامل

Mid- to long-term outcome of cementless total hip arthroplasty in younger patients.

PURPOSE To assess mid- to long-term outcomes of cementless primary total hip arthroplasty (THA) in younger patients. METHODS Records of 28 women and 34 men (75 hips) aged 18 to 55 (mean, 38) years who underwent primary THA using a hydroxyapatite-coated stem and a threaded cup and had been followed up for a mean of 10 (6-15) years were reviewed. 13 of the patients had bilateral THAs. Clinical ...

متن کامل

Cementless total hip arthroplasty using the omnifit system: An 8.2 year follow-up study of 166 hips.

One hundred and sixty-six cementless primary total hip arthroplasties were performed in 133 patients with porous coated Omnifit prosthesis. The average age was 49.7 years. The mean follow-up period was 8.2 years with a minimum of 5 years. Good to excellent clinical results were achieved in 93% of patients. The overall revision rate was 5.4%. Radiographically, bone ingrowth occurred in all unrev...

متن کامل

Biotribology of a vitamin E-stabilized polyethylene for hip arthroplasty - Influence of artificial ageing and third-body particles on wear.

The objective of our study was to evaluate the influence of prolonged artificial ageing on oxidation resistance and the subsequent wear behaviour of vitamin E-stabilized, in comparison to standard and highly cross-linked remelted polyethylene (XLPE), and the degradation effect of third-body particles on highly cross-linked remelted polyethylene inlays in total hip arthroplasty. Hip wear simulat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015