A comparison of 2 methods of continuous aerosol administration during methacholine challenge testing.

نویسندگان

  • Thomas S Hurst
  • Donald W Cockcroft
  • Victor D Hannah
  • Beth E Davis
چکیده

BACKGROUND Exposure to the bronchoconstricting agent methacholine is a potential hazard to technical staff during methacholine challenge testing, which remains a useful and frequently performed test. There are several methods of performing the test. One of the 2 methods listed in the American Thoracic Society's guidelines is the 2-min tidal-breathing method. The methacholine can be inhaled using one of several methods. The loosely-fitting-mask method is likely to produce more contamination of the local environment than a filtered exhalation system. METHODS We tested 2 variations of the tidal-breathing method of measuring the methacholine provocational concentration (PC(20), the dose that produces a 20% decrease in forced expiratory volume in the first second). One involved use of the open-mask technique and the other a T-piece-and-filter system that precluded the release of methacholine-containing droplets into the environment. We performed duplicate methacholine challenge tests with 10 subjects who had a wide range of PC(20). The tests were done in random order, and each subject performed one test using the mask and one using the T-piece/filter system. RESULTS With the mask system the geometric mean PC(20) was 4.7 mg/mL, versus 5.1 mg/mL with the T-piece-filter system (p = 0.36). These values are very close and would not be substantially different clinically. CONCLUSION The 2 methods are equivalent, and the low cost of the products used in the T-piece/filter method makes it suitable for reducing technician exposure to methacholine, using potentially completely disposable components.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methacholine challenge: comparison of two methods.

BACKGROUND Guidelines for the 2-min tidal-breathing and the five-breath dosimeter methods for methacholine challenge have recently been published by the American Thoracic Society (ATS). Although subjects are exposed to twice as much aerosol at any given concentration during the tidal-breathing method compared to the dosimeter method, they were thought to give equivalent results. OBJECTIVE To ...

متن کامل

Inhalational challenge using hypertonic saline in asthmatic subjects: a comparison with responses to hyperpnoea, methacholine and water.

Non-isotonic aerosols are being used increasingly for bronchial provocation testing in patients with asthma. We investigated changes in forced expiratory volume in one second (FEV1) in response to inhaling ultrasonically nebulized 4.5% saline in 10 normal subjects and 68 subjects with asthma. A comparison of the sensitivity to this challenge was made with sensitivity to challenge with methachol...

متن کامل

Methacholine bronchial challenge using a dosimeter with controlled tidal breathing.

A new inhalation synchronised dosimeter triggered by low inspiratory flow rates has been assessed. The methacholine challenge test using dosimeter nebulisation with controlled tidal breathing was compared with continuous nebulisation using De Vilbiss No 40 nebulisers with deep inhalations in 11 asthmatic subjects. Within subject PD20 FEV1 values were lower with the dosimeter method than with th...

متن کامل

Aerosol Use in the Pulmonary Function Lab.

Aerosolized medications are frequently used in the pulmonary function laboratory. The 2 most common implementations are bronchodilators and bronchial challenge agents. Bronchodilator administration is not well standardized, largely because of the various methods of delivery available for clinical practice. Metered-dose inhalers used with spacer devices are the most common route for bronchodilat...

متن کامل

A clinical and structural comparison of industrial methacholine and provocholine.

Methacholine, provided by industrial sources, has traditionally been used in studies of airways responsiveness. In 1986, a Food and Drug Administration approved formulation of methacholine (Provocholine) was released and replaced industrial methacholine in many pulmonary laboratories. To determine whether methacholine and Provocholine cause an equivalent degree of bronchoconstriction, a double ...