An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology
نویسندگان
چکیده
The ionophore 1,4,7,10,13-penta(n-octyl)-1,4,7,10,13-pentaazacyclopentadecane (L) was used for the development of miniaturised perchlorate-selective electrodes in thickfilm technology. Different PVC membranes containing L and the plasticizers o-nitrophenyl octyl ether (NPOE), dibutyl phthalate (DBP), bis(2-ethylhexyl)sebacate (DOS) and dibutyl sebacate (DBS) were prepared and placed on a graphite working electrode manufactured by using thick film serigraphic technology. The perchlorate selective electrode containing DBS as plasticizer showed a potentiometric Nernstian response of -57 mV per decade in a range of perchlorate concentration from 1 x 10 to 1 x 10 M with a detection limit of 5 x 10 M. The ion selective electrodes containing DBP and NPOE as plasticizers exhibit a working range from 6.3 x 10 to 1 x 10 M and 7.4 x 10 to 1 x 10 M for perchlorate, respectively, with a detection limit of ca. 2.2 x 10 M. For all three electrodes a response time of ca. 5 s was found. The prepared electrodes do not show appreciable decay of the slope for at least 25 days. Potentiometric selectivity coefficients (log KClO4,X) with respect to the primary anion perchlorate were evaluated using the fixed interference method. These coefficients are of the order of 10 or smaller, indicating the relatively poor interference of the different anions studied.
منابع مشابه
Highly Selective Perchlorate Membrane Electrode Based on Synthesized Schiff Base Complex
In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of for perchlorate. The lim...
متن کاملUsing electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode
In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...
متن کاملMiniaturized, Planar Ion-selective Electrodes Fabricated by Means of Thick-film Technology
Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thinand thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and ...
متن کاملStripping analysis of nanomolar perchlorate in drinking water with a voltammetric ion-selective electrode based on thin-layer liquid membrane.
A highly sensitive analytical method is required for the assessment of nanomolar perchlorate contamination in drinking water as an emerging environmental problem. We developed the novel approach based on a voltammetric ion-selective electrode to enable the electrochemical detection of "redox-inactive" perchlorate at a nanomolar level without its electrolysis. The perchlorate-selective electrode...
متن کاملMeasurement and Modeling of Mean Ionic Activity Coefficient in Aqueous Solution Containing NaNO3 and Poly Ethylene Glycol
Potentiometric investigation on {H2O+NaNO3+PEG1500} mixtures were made at T=308.15K, using electrochemical cells with two ion-selective electrodes, (Na+ glass) as the cation ion-selective electrode against (NO3- solvent-polymer PVC) as the anion ion-selective electrode. The mean ionic activity coefficients of NaNO3 were measu...
متن کامل