Trends in image quality in high magnification digital specimen cabinet radiography.
نویسندگان
چکیده
Advances in microfocus X-ray tube design together with the availability of high resolution charge coupled device (CCD) detectors have led to the introduction of high magnification digital specimen cabinets for the examination of tissue samples. This paper explores the effect that the high magnification geometry permitted by such units has upon image quality in terms of phase contrast edge enhancement, spatial resolution and the appearance of test phantom images. Phase contrast effects and spatial resolution were studied using a previously established method (using edge profiles) and by computing the system spatial frequency response at various geometries. It was demonstrated that the magnitude of the phase contrast enhancement effect reaches a stable maximum at a magnification of x 4. It has also been shown that a continual increase in both the spatial resolution together with an improved signal to noise ratio occurs up to the maximum permissible magnification geometry, with effects of focal spot blur being negligible. In practice, the limited size of the digital detector and the difficulty of object alignment can constrain the use of the very high magnification option.
منابع مشابه
Evaluation of Image Magnification in Digital Panoramic Radiography
Introdouction: The aim of the present study was to investigate image magnification in digital panoramic radiography and assess the effect of anatomical sites on the magnification in both males and females. Materials and methods: In this retrospective study, digital panoramic radiographs of 48 patients with 202 implants were investigated. Implant diameter and length were measured on pan...
متن کاملEffects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography
Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...
متن کاملQuality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کاملAccuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites
The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...
متن کاملImage quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study
Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of radiology
دوره 79 939 شماره
صفحات -
تاریخ انتشار 2006