Mathematically Reliable Stereological Measurement of Motion Corrected Fetal Brain Volume

نویسندگان

  • Devasuda Anblagan
  • Kaiming Yin
  • Rebecca Reynolds
  • Fiona Denison
  • Mark Bastin
  • Colin Studholme
  • Jane Norman
  • Scott Semple
  • Neil Roberts
چکیده

Submission No: 1500 Authors: Devasuda Anblagan1, Kaiming Yin1, Rebecca Reynolds1, Fiona Denison1, Mark Bastin1, Colin Studholme2, Jane Norman1, Scott Semple1, Neil Roberts1 Institutions: 1University of Edinburgh, Edinburgh, United Kingdom, 2University of Washington, Seattle, WA, United States Introduction: Motion correction is now possible for fetal brain (FB) MRI studies in both the 2nd and 3rd trimester, however techniques to segment these images are still under development. We describe the first application and practicality, time efficiency and precision of Isotropic Cavalieri (IsoC), Invariator (InV) and Discretized Nucleator (DNuc) stereology methods for estimating fetal brain volume (FBV) on motion corrected 3D images. Methods: 15 pregnant women were recruited and gave informed consent to be imaged on a MAGNETOM Verio 3T system (Siemens AG, Germany): 9 at 24–26 weeks and 6 at 35–37 weeks gestation. HASTE acquisitions of the fetal brain were obtained (25–45 slices, TE = 94 ms and TR = 4200 ms, SAR<2.0 W kg-1, 0.55×0.55×3 mm3 voxels) three times in each of axial, sagittal and coronal scanning directions. The image series were motion corrected using Slimmer tool1 to form a single 3D high-resolution brain image (1×1×1 mm3 voxels) and used to estimate FBV using stereological methods2 (IsoC, InV and DNuc) using Analyze 10.0 software (MAYO Foundation, USA). Beginning from a random starting position, the IsoC method involves sampling the brain with a series of images a constant distance T apart along a random orientation in 3D. Sections were analyzed using point counting. The InV method alternatively requires only a single isotropic section to be obtained through a fixed point in the 3D image volume. Orthogonal chord lengths within the brain are then measured using a T-shaped measurement tool as shown in Fig. 1b (yellow line). The DNuc method is similar to InV, except that now the length of the radial arm of the T-shaped measurement tool is directly measured from the fixed point to each test point lying within the brain (Fig. 1b, blue line). All three methods were applied in three random mutually orthogonal orientations. The Cavalieri method was also applied directly to the original axial, sagittal, and coronal HASTE datasets. 10/01/2013 18:06 OHBM Page 2 of 3 https://ww4.aievolution.com/hbm1301/index.cfm?do=abs.viewAbs&subView=1&abs=1373 Results: Reconstruction of the fetal brain was possible in all cases except for a dataset acquired at 25 weeks due to excessive fetal motion. Efficiency measures (time, precision) was lowest for the InV (10–15 minutes, 2–37%), followed by IsoC and DNuc (both 5–10 minutes, 0–5% and 4–37% respectively). As expected, there was excellent agreement between the FBV estimates obtained from each of the orthogonal IsoC series, and much greater variation between the FBV estimates obtained from the 3orthogonal InV or DNuc sections but with the mean always close to the results obtained using the IsoC method. Estimates obtained by applying the Cavalieri method to the uncorrected datasets were variable depending on the scale of motion (Fig. 2). The quality of fetal head motion correction using SLIMMER depends greatly on the degree of fetal motion; this was generally greater during the 2nd trimester and more challenging to correct for than in the 3rd trimester when the fetal head is frequently engaged in the maternal pelvis. Furthermore, even when the motion correction algorithm has been successfully applied, the gyri and sulci of the fetal brain may still not be clearly depicted on the reconstructed 3D image. This affects the ease of performing surface area measurement (Fig. 1d), which as well as being interesting in its own right, is a prerequisite for application of the mathematical formula developed by Cruz-Orive2 for predicting the precision of volume estimates obtained using the IsoC method. Accordingly, surface area measurements were only possible on 3 datasets from 2nd and 6 from 3rd trimester. 10/01/2013 18:06 OHBM Page 3 of 3 https://ww4.aievolution.com/hbm1301/index.cfm?do=abs.viewAbs&subView=1&abs=1373 Conclusions: We have demonstrated high levels of agreement between FBV measurements obtained by applying three new stereological methods to motion corrected 3D MR images of the fetal brain. IsoC is the most precise method and is recommended for detailed studies in individual subjects while InV and DNuc could be used in measuring the change in mean brain volume in a cohort of subjects. Modeling and Analysis Methods: Other Methods [1] Kim, K. (2010), ‘Intersection Based Motion Correction of Multi-Slice MRI for 3D in utero Fetal Brain Image Formation’, IEEE Trans. Med. Imaging, vol. 29, no. 1, pp. 146-158. [2] L.M.Cruz-Orive (2010), ‘Stereology of isolated objects with the invariator’, Journal of Microscopy, vol. 240, no. 2, pp. 94-110.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Volumetric Changes of Rat's Embryonic Renal Glomeruli, Cortex and Medulla Following Lithium Carbonate Administration by Means of Stereological Method

Purpose: To study the effects of lithium on the fetal rat's kidney and determine volumetric changes by an unbiased stereological method. Materials and Methods: Thirty female and ten male Sprague dawley rats were chosen. Following cohabitation and observation of spermatozoa in the vaginal smear, the pregnant rats were divided into three groups (n=10). Treatment and control groups received 50 mg...

متن کامل

Automated fetal brain segmentation from 2D MRI slices for motion correction

Motion correction is a key element for imaging the fetal brain in-utero using Magnetic Resonance Imaging (MRI). Maternal breathing can introduce motion, but a larger effect is frequently due to fetal movement within the womb. Consequently, imaging is frequently performed slice-by-slice using single shot techniques, which are then combined into volumetric images using slice-to-volume reconstruct...

متن کامل

Sexual Dimorphism in Human Brain Weight and Volume of Gray and White Matter in Normal and Neurodegenerative Subjects - A Stereological and Macroscopic Study

Purpose: This study is designed to determine the sex differences in brain weight and volume of left hemisphere and its gray and white matters in right-handed normal subjects and the right-handed subjects which were suffered from Alzheimer and Parkinson diseases. Materials and Methods: This study was performed on 72 normal human brains (38 male, 34 female), 11 brains suffered from Alzheimer (4 ...

متن کامل

Sexual Dimorphism in Volume of Precentral Cortex of Human Brain in Normal Subject who are Suffering from Alzheimer and Parkinson-A Stereological and Macroscopical Study

Purpose: This study is designed to determine the sex difference in volume of precentral cortex of left hemisphere in right-handed normal subjects and the right-handed subjects which are suffering from Alzheimer and Parkinson diseases. Materials and Methods: This study was performed on 72 normal human brains (38 males, 34 females), 11 human brains suffering from Alzheimer (4 males, 7 females), ...

متن کامل

Inter-slice motion correction using spatiotemporal interpolation for functional magnetic resonance imaging of the moving fetus

Fetal motion continues to be one of the major artifacts in in-utero functional MRI; interestingly few methods have been developed to address fetal motion correction. In this study, we propose a robust method for motion correction in fetal fMRI by which both inter-slice and inter-volume motion artifacts are jointly corrected. To accomplish this, an original volume is temporally split into odd an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016