An alternative sensor-based method for glucose monitoring in children and young people with diabetes
نویسندگان
چکیده
OBJECTIVE To determine accuracy, safety and acceptability of the FreeStyle Libre Flash Glucose Monitoring System in the paediatric population. DESIGN, SETTING AND PATIENTS Eighty-nine study participants, aged 4-17 years, with type 1 diabetes were enrolled across 9 diabetes centres in the UK. A factory calibrated sensor was inserted on the back of the upper arm and used for up to 14 days. Sensor glucose measurements were compared with capillary blood glucose (BG) measurements. Sensor results were masked to participants. RESULTS Clinical accuracy of sensor results versus BG results was demonstrated, with 83.8% of results in zone A and 99.4% of results in zones A and B of the consensus error grid. Overall mean absolute relative difference (MARD) was 13.9%. Sensor accuracy was unaffected by patient factors such as age, body weight, sex, method of insulin administration or time of use (day vs night). Participants were in the target glucose range (3.9-10.0 mmol/L) ∼50% of the time (mean 12.1 hours/day), with an average of 2.2 hours/day and 9.5 hours/day in hypoglycaemia and hyperglycaemia, respectively. Sensor application, wear/use of the device and comparison to self-monitoring of blood glucose were rated favourably by most participants/caregivers (84.3-100%). Five device related adverse events were reported across a range of participant ages. CONCLUSIONS Accuracy, safety and user acceptability of the FreeStyle Libre System were demonstrated for the paediatric population. Accuracy of the system was unaffected by subject characteristics, making it suitable for a broad range of children and young people with diabetes. TRIAL REGISTRATION NUMBER NCT02388815.
منابع مشابه
Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings
Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...
متن کاملDetermining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings
Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...
متن کاملDesigning and Assessment Suuccession Management Model In The Institute For The Intellectual Development Of Children And Young Adults
Abstract The purpose of this study was to Designing and Assessment Suuccession Management Model of managers in The Intellectual Development Of Children And Young Adults. This research was of Mixed Method and exploratory type. In the qualitative part, by using the case and exploratory study method, the dimensions and components of the succession were identified and in the quantitative part, the...
متن کاملDesigning and Assessment Suuccession Management Model In The Institute For The Intellectual Development Of Children And Young Adults
Abstract The purpose of this study was to Designing and Assessment Suuccession Management Model of managers in The Intellectual Development Of Children And Young Adults. This research was of Mixed Method and exploratory type. In the qualitative part, by using the case and exploratory study method, the dimensions and components of the succession were identified and in the quantitative part, the...
متن کاملThe Medtronic Minimed Gold continuous glucose monitoring system: an effective means to discover hypo- and hyperglycemia in children under 7 years of age.
BACKGROUND The glycemic patterns of children less than 7 years with type 1 diabetes have not been well studied using continuous glucose monitoring. Our goal was to assess the incidence of hypoglycemia as well as postprandial glycemic patterns in this age group utilizing continuous glucose monitoring. METHODS Nineteen children used the Medtronic MiniMed (Northridge, CA) CGMS System Gold on thr...
متن کامل