Improvement of HS-SPME for analysis of volatile organic compounds (VOC) in water samples by simultaneous direct fiber cooling and freezing of analyte solution.
نویسندگان
چکیده
The sensitivity and precision of headspace solid-phase micro extraction (HS-SPME) at an analyte solution temperature (T (as)) of +35 degrees C and a fiber temperature (T (fiber)) of +5 degrees C were compared with those for HS-SPME at T (as) and T (fiber) of -20 degrees C for analysis of the volatile organic compounds benzene, 1,1,1-trichloroethane, trichloroethylene, toluene, o-xylene, ethylbenzene, m/p-xylene, and tetrachloroethylene in water samples. The effect of simultaneous fiber cooling and analyte solution freezing during extraction was studied. The compounds are of different hydrophobicity, with octanol/water partition coefficients (Kow) ranging from 126 and 2511. During a first set of experiments the polydimethylsiloxane (PDMS) SPME fiber was cooled to +5 degrees C with simultaneous heating of the aqueous analyte solution to +35 degrees C. During a second set of experiments, both SPME fiber holder and samples were placed in a deep freezer maintained at -20 degrees C for a total extraction time of 30 min. After approximately 2 min the analyte solution in the vial began to freeze from the side inwards and from the bottom upwards. After approximately 30 min the solution was completely frozen. Analysis of VOC was performed by coupling HS-SPME to gas chromatography-mass spectrometry (GC-MS). In general, i.e. except for tetrachloroethylene, the sensitivity of HS-SPME increased with increasing compound hydrophobicity at both analyte solution and fiber temperatures. At T (as) of +35 degrees C and T (fiber) of +5 degrees C detection limits of HS-SPME were 0.5 microg L(-1) for benzene, 1,1,1-trichloroethane, trichloroethylene, and tetrachloroethylene, 0.125 microg L(-1) for toluene, and 0.025 microg L(-1) for ethylbenzene, m/p-xylene, and o-xylene. In the experiments with T (as) and T (fiber) of -20 degrees C, detection limits were reduced for compounds of low hydrophobicity (Kow<501), for example benzene, toluene, 1,1,1-trichloroethane, and trichloroethylene. In the concentration range 0.5-62.5 microg L(-1), the sensitivity of HS-SPME was enhanced by a factor of approximately two for all compounds by performing the extraction at -20 degrees C. A possible explanation is that freezing of the water sample results in higher concentration of the target compounds in the residual liquid phase and gas phase (freezing-out), combined with enhanced adsorption of the compounds by the cooled fiber. The precision of HS-SPME, expressed as the relative standard deviation and the linearity of the regression lines, is increased for more hydrophobic compounds (Kow>501) by simultaneous direct fiber cooling and freezing of analyte solution. Background contamination during analysis is reduced significantly by avoiding the use of organic solvents.
منابع مشابه
Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review
Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...
متن کاملSolid-Phase Microextraction and the Human Fecal VOC Metabolome
The diagnostic potential and health implications of volatile organic compounds (VOCs) present in human feces has begun to receive considerable attention. Headspace solid-phase microextraction (SPME) has greatly facilitated the isolation and analysis of VOCs from human feces. Pioneering human fecal VOC metabolomic investigations have utilized a single SPME fiber type for analyte extraction and a...
متن کاملComparative Analyses of the Volatile Components of Citrus Aurantium L. Flowers Using Ultrasonic-Assisted Headspace SPME and Hydrodistillation Combined with GC-MS and Evaluation of their Antimicrobial Activities
The volatile components of Citrus aurantium L. flowers were characterized by GC-MS with two different extraction techniques, hydrodistillation (HD) and ultrasonic-assisted headspace solid phase microextraction (UA-HS-SPME). In the SPME method, the volatile components of the samples, irradiated by ultrasonic radiation, were collected on a polydimethyl siloxane (PDMS) commercial fiber as...
متن کاملCharacterization of volatile organic compounds and odors by in-vivo sampling of beef cattle rumen gas, by solid-phase microextraction, and gas chromatography-mass spectrometry-olfactometry.
Volatile organic compounds (VOCs) and odors in cattle rumen gas have been characterized by in-vivo headspace sampling by solid-phase microextraction (SPME) and analysis by gas chromatography-mass spectrometry-olfactometry (GC-MS-O). A novel device enabling headspace SPME (HS-SPME) sampling through a cannula was designed, refined, and used to collect rumen gas samples from steers. A Carboxen-pol...
متن کاملCooling/heating-assisted headspace solid-phase microextraction of polycyclic aromatic hydrocarbons from contaminated soils.
A simple, low-cost, and effective cooling/heating-assisted headspace solid-phase microextraction (CHA-HS-SPME) device, capable of direct cooling the fiber to low temperatures and simultaneous heating the sample matrix to high temperatures, was fabricated and evaluated. It was able to cool down the commercial and handmade fibers for the effective tapping of volatile and semi-volatile species in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 386 5 شماره
صفحات -
تاریخ انتشار 2006