Full-field microimaging with 8 keV X-rays achieves a spatial resolutions better than 20 nm.

نویسندگان

  • Tsung-Yu Chen
  • Yu-Tung Chen
  • Cheng-Liang Wang
  • Ivan M Kempson
  • Wah-Keat Lee
  • Yong S Chu
  • Y Hwu
  • G Margaritondo
چکیده

Fresnel zone plates (450 nm thick Au, 25 nm outermost zone width) used as objective lenses in a full field transmission reached a spatial resolution better than 20 nm and 1.5% efficiency with 8 keV photons. Zernike phase contrast was also realized without compromising the resolution. These are very significant achievements in the rapid progress of high-aspect-ratio zone plate fabrication by combined electron beam lithography and electrodeposition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zone-doubled Fresnel zone plates for high-resolution hard X-ray full-field transmission microscopy

Full-field transmission X-ray microscopy is a unique non-destructive technique for three-dimensional imaging of specimens at the nanometer scale. Here, the use of zone-doubled Fresnel zone plates to achieve a spatial resolution better than 20 nm in the hard X-ray regime (8-10 keV) is reported. By obtaining a tomographic reconstruction of a Ni/YSZ solid-oxide fuel cell, the feasibility of perfor...

متن کامل

Application of large-area avalanche photodiodes to energy-dispersive x-ray fluorescence analysis

The performance of several large-area avalanche photodiodes (LAAPDs) for application to x-ray spectrometry at room temperature was investigated. Optimum detector performance was obtained for gains of about 50–70. Good energy linearity of the LAAPDs’ response to x-rays was observed up to energies of about 25 keV. For this energy range the space charge effects are negligible for gains below 100–1...

متن کامل

Recent progress of avalanche photodiodes in high-resolution X-rays and γ-rays detection

We have studied the performance of large area avalanche photodiodes (APDs) recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and γrays detections. We show that reach-through APD can be an excellent soft X-ray detector operating at room temperature or moderately cooled environment. We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV X-rays, and ...

متن کامل

Efficient focusing of 8 keV X-rays with multilayer Fresnel zone plates fabricated by atomic layer deposition and focused ion beam milling

Fresnel zone plates (FZPs) recently showed significant improvement by focusing soft X-rays down to ~10 nm. In contrast to soft X-rays, generally a very high aspect ratio FZP is needed for efficient focusing of hard X-rays. Therefore, FZPs had limited success in the hard X-ray range owing to difficulties of manufacturing high-aspect-ratio zone plates using conventional techniques. Here, employin...

متن کامل

Thick CZT Detectors for Space-Borne X-ray Astronomy

Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to ∼600 keV. In this paper, we briefly review the historical development of detectors used in Xray astronomy. Subsequently, we present an evaluation of CZT detectors ...