Nonlinear self-calibrated phase-contrast correction in quantitative cardiac imaging

نویسندگان

  • Ek T Tan
  • Anja C Brau
  • Christopher J Hardy
چکیده

Background Residual background phase in cardiac phase-contrast (PC) imaging introduces velocity errors that bias quantitative flow measurements [1]. While the bias can be offset using static phantoms [2], improved workflow is realized if self-calibrated correction is performed by fitting the phase of static tissue from the in vivo images. However, the residual phase can be nonlinear in space and the vessels of interest, e.g. great vessels, are often far from any static tissue in the image. This means that a linear fit [3] can sometimes result in under-fitting, while fitting with higher spatial-orders can result in over-fitting. Methods We propose a nonlinear self-calibrated approach, which assumes a nonlinear shape. This follows observations that the residual phase is similar in shape to that of the concomitant field. Therefore as compared to linear fitting that uses 4 terms (constant + XYZ), the nonlinear-fit has 5 terms that also include the concomitant field. Further steps are taken to improve the fit, which include iterative removal of outliers that frequently occur at tissue boundaries, and weighting velocities from the quiescent cardiac phase more heavily to reduce effects from flow artifacts at systole. To prevent over-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonlinear self-calibrated phase contrast correction in pediatric and congenital cardiovascular magnetic resonance imaging

Background Phase contrast (PC) MR flow measurements are affected by phase offset errors due to local eddy currents. Performing error correction using an MR phantom prolongs each CMR study and can impede scanner workflow. Recently, a novel post-hoc nonlinear self-calibrated PC correction algorithm has been developed that can be applied to PC flow data, with equivalence to phantom correction and ...

متن کامل

Simulation and patient studies of scatter correction in cardiac SPECT imaging

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

Determination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging

Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014