Self-refocused adiabatic pulse for spin echo imaging at 7 T.
نویسندگان
چکیده
Spin echo pulse sequences are used to produce clinically important T(2) contrast. However, conventional 180° radiofrequency pulses required to generate a spin echo are highly susceptible to the B(1) inhomogeneity at high magnetic fields such as 7 Tesla (7 T), resulting in varying signal and contrast over the region of interest. Adiabatic 180° pulses may be used to replace conventional 180° pulses in spin echo sequences to provide greater immunity to the inhomogeneous B(1) field at 7 T. However, because the spectral profile of an adiabatic 180° pulse has nonlinear phase, pairs of these pulses are needed for proper refocusing, resulting in increased radiofrequency power deposition and long minimum echo times. We used the adiabatic Shinnar Le-Roux method to generate a matched-phase adiabatic 90°-180° pulse pair to obviate the need for a second adiabatic 180° pulse for phase refocusing. The pulse pair was then reformulated into a single self-refocused pulse to minimize the echo time, and phantom and in vivo experiments were performed to validate pulse performance. The self-refocused adiabatic pulse produced transmit profiles that were substantially more uniform than those achieved using a conventional spin echo sequence.
منابع مشابه
Ultrahigh field single-refocused diffusion weighted imaging using a matched-phase adiabatic spin echo (MASE).
PURPOSE To improve ultrahigh field diffusion-weighted imaging (DWI) in the presence of inhomogeneous transmit B1 field by designing a novel semi-adiabatic single-refocused DWI technique. METHODS A 180° slice-selective, adiabatic radiofrequency (RF) pulse of 4 ms duration was designed using the adiabatic Shinnar-Le Roux algorithm. A matched-phase slice-selective 90° RF pulse of 8 ms duration w...
متن کاملA simple low-SAR technique for chemical-shift selection with high-field spin-echo imaging.
We have discovered a simple and highly robust method for removal of chemical shift artifact in spin-echo MR images, which simultaneously decreases the radiofrequency power deposition (specific absorption rate). The method is demonstrated in spin-echo echo-planar imaging brain images acquired at 7 T, with complete suppression of scalp fat signal. When excitation and refocusing pulses are suffici...
متن کاملSelf-refocused spatial-spectral pulse for positive contrast imaging of cells labeled with SPIO nanoparticles.
MRI has been used extensively to noninvasively track the location of cells labeled with superparamagnetic iron-oxide nanoparticles (SPIOs) in vivo. Typically, SPIOs are employed as a negative contrast agent which makes it difficult to differentiate labeled cells from extraneous sources of inhomogeneity and actual voids in the image. As a result, several novel approaches have been put forth to o...
متن کاملPerformance of single spin-echo and doubly refocused diffusion-weighted sequences in the presence of eddy current fields with multiple components.
Echo-planar diffusion-weighted images can display significant geometric distortions due to eddy current fields. Several preparation schemes have been proposed, which can null eddy currents with a single time constant. The aim of this work was to compare the performance of three such pulse sequences in the presence of multiple components and investigate whether affine registration is capable of ...
متن کاملAn adiabatic multiple spin-echo pulse sequence: removal of systematic errors due to pulse imperfections and off-resonance effects.
Application of AFP (adiabatic fast passage) pulses for removal of systematic errors associated with multiple spin-echo sequences is demonstrated. The adiabatic fast passage pulses facilitate minimization of cumulative pulse errors for all three components of magnetization. It is also shown that off-resonance effects present in conventional CPMG sequences which degrade image quality in magnetic ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 67 4 شماره
صفحات -
تاریخ انتشار 2012