Direct intra-abdominal pressure monitoring via piezoresistive pressure measurement: a technical note

نویسندگان

  • Jens Otto
  • Daniel Kaemmer
  • Marcel Binnebösel
  • Marc Jansen
  • Rolf Dembinski
  • Volker Schumpelick
  • Alexander Schachtrupp
چکیده

BACKGROUND Piezoresistive pressure measurement technique (PRM) has previously been applied for direct IAP measurement in a porcine model using two different devices. Aim of this clinical study was to assess both devices regarding complications, reliability and agreement with IVP in patients undergoing elective abdominal surgery. METHODS A prospective cohort study was performed in 20 patients randomly scheduled to receive PRM either by a Coach-probe or an Accurate(++)-probe (both MIPM, Mammendorf, Germany). Probes were placed on the greater omentum and passed through the abdominal wall paralleling routine drainages. PRM was compared with IVP measurement by t-testing and by calculating mean difference as well as limits of agreement (LA). RESULTS There were no probe related complications. Due to technical limitations, data could be collected in 3/10 patients with Coach and in 7/10 patients with Accurate++. Analysis was carried out only for Accurate++. Mean values did not differ to mean IVP values. Mean difference to IVP was 0.1 +/- 2.8 mmHg (LA: -5.5 to 5.6 mmHg). CONCLUSION Direct IAP measurement was clinically uneventful. Although results of Accurate++ were comparable to IVP, the device might be too fragile for IAP measurements in the clinical setting. Local ethical committee trial registration: EK2024.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Intra-abdominal Pressure Measurement and Physical Exam for Diagnosis of Surgery Indication in Patients with Abdominal Compartment Syndrome due to Blunt Trauma

Background & Aims: Increase in abdominal pressure can lead to the so-called intra–abdominal compartment syndrome (ACS) that is often observed during the first 24 hours after sever abdominal trauma and surgery. Measurement of the intra abdominal pressure through the bladder as a non-invasive measurement can provide a quick and accurate assessment of abdominal pressure changes. This study was per...

متن کامل

Pressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model

Introduction. Intra-abdominal pressure (IAP) measurement is an indispensable tool for the diagnosis of abdominal hypertension. Different techniques have been described in the literature and applied in the clinical setting. Methods. A porcine model was created to simulate an abdominal compartment syndrome ranging from baseline IAP to 30 mmHg. Three different measurement techniques were applied, ...

متن کامل

Abdominal compartment syndrome monitoring in major burn patients with Siriraj device catheter.

Abdominal compartment syndrome (ACS) is consistently reported to have significant morbidity and mortality. Major burn patients who receive massive fluid resuscitation are at high-risk for this condition. Close monitoring of ACS is necessary for these patients. Prolonged unrelieved intra-abdominal pressure (IAP) at greater than 20 mmHg can produce significant morbidity and mortality. The most wi...

متن کامل

A Prospective Study of Intra Abdominal Pressure (IAP) Monitoring to Predict Severity and Prognosis in Patients of Acute Severe Pancreatitis

In cases of acute severe pancreatitis mortality rate remains high. Few of these patients develop increased intra abdominal pressure. This study used utility of intra abdominal pressure monitoring to assess severity of severe acute pancreatitis and its comparison with CT severity index and to predict prognosis of patients of acute severe pancreatitis by measuring intra abdominal pressure and to ...

متن کامل

An Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams

This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Surgery

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009