Feasibility of magnetic bead technology for concentration of mycobacteria in sputum prior to fluorescence microscopy

نویسندگان

  • Heidi Albert
  • Patrick J Ademun
  • George Lukyamuzi
  • Barnabas Nyesiga
  • Yukari Manabe
  • Moses Joloba
  • Stuart Wilson
  • Mark D Perkins
چکیده

BACKGROUND Direct sputum smear microscopy is the mainstay of TB diagnosis in most low and middle income countries, and is highly specific for Mycobacterium tuberculosis in such settings. However it is limited by low sensitivity, particularly in HIV co-infected patients. Concentration by centrifugation has been reported to be more sensitive than direct smear preparation, but is only suitable for referral laboratories. Simpler concentration methods that could be applied in peripheral laboratories are urgently needed. METHODS We evaluated the feasibility of an early prototype ligand-coated magnetic bead technology to concentrate M. tuberculosis prior to detection by LED-based fluorescence microscopy compared with direct Ziehl-Neelsen microscopy and direct and concentrated fluorescence microscopy in a reference laboratory in Kampala, Uganda. Results were compared with MGIT 960 liquid culture and Lowenstein-Jensen culture. RESULTS Compared to culture, concentrated FM had significantly higher sensitivity than direct ZN (74.8% and 51.4%), magnetic bead-FM (65.4%) and direct FM (58.9%). The sensitivity of magnetic bead FM was significantly higher than direct ZN (p<0.001) but not significantly higher than direct FM (p=0.210). The specificity of magnetic bead FM and concentrated FM was significantly lower than direct ZN (88.6%, 94.3% and 98.9% respectively) and direct FM (99.4%). There was no significant difference in specificity between magnetic bead FM and concentrated FM. Allowing for blinded resolution of discrepant results, the specificity of magnetic bead FM increased to 93.1%. Direct microscopy was simpler than concentrated FM and Magnetic bead FM which both had a similar number of steps. CONCLUSION The sensitivity of the early prototype magnetic bead FM was lower than concentrated FM, similar to direct FM, and significantly higher than direct ZN. Both magnetic bead and concentration by centrifugation led to reduced specificity compared with the direct smear methods. Some magnetic bead FM false positive results were not easily explained and should be further investigated. The prototype version of the magnetic bead procedure tested here was of similar complexity to concentration by centrifugation. As such, if the sensitivity of the magnetic bead FM could be improved in future versions of the technology, this may offer a viable alternative to centrifugation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of electrospinning conditions for magnetic poly (acrylonitrile- co- acrylic acid) nanofibers

Magnetic poly (acrylonitrile-co-acrylic acid) (PAN-co-AA) composite nanofibers with different proportions of magnetic nanoparticles (MNPs) were fabricated using electrospinning technique. Electrospinning conditions like polymeric concentration, applied voltage, feeding rate, working distance, and collector type were explored and optimized to produce ultrafine- uniform size and bead free nanofib...

متن کامل

Evaluation of Advanced Gravity and Magnetic Concentration of a PGM Tailings Waste for Chromite Recovery

This research was aimed at evaluating the efficiency of advanced gravity and magnetic separations on the recovery of chromite from the fine Platinum Group Metals (PGM) tailings consisting of particles 80% passing 75 µm with about 45% being >45 µm resulting in high chromite losses. The PGM plant tailings were subjected to X-ray fluorescence, scanning electron microscopy and particle size dis...

متن کامل

Highly Sensitive FRET-Based Fluorescence Immunoassay for Detecting of Aflatoxin B1 Using Magnetic/Silica Core-Shell as a Signal Intensifier

Background: Recently, some new nanobiosensors using different nanoparticles or microarray systems for detection of mycotoxins have been designed . However, rapid, sensitive and early detection of aflatoxicosis would be very helpful to distinguish high-risk persons. Objectives: We report a highly sensitive competitive immunoassay using magnetic/silica core shell as a signal intensifier for the d...

متن کامل

مقایسه ارزش تشخیصی اسمیر خلط به دو روش میکروسکوپی در بیماران مشکوک به سل ریوی با و بدون استفاده ازهیپوکلریت سدیم

Background and purpose: Direct smear microscopy is the most common method of detecting tuberculosis with 70% sensitivity in best conditions, therefore, researches have always focused on improving the sensitivity of sputum smear. This study aimed at comparing the diagnostic value of sputum smear using light microscopy and fluorescence microscopy without sodium hypochlorite in patients with suspe...

متن کامل

The Study of Improvement of Dispersive Soil Using Magnetic Field

In this study, the feasibility of using magnetic technology to reduce the dispersion of soil has been investigated. The reference treatment was potable water and 3 magnetic water devices (with different magnetic intensities) were used for magnetizing the potable water. The results showed that the magnetic field has a significant effect in order of 5 percent on increasing of magnesium concentrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011