Orthodontic miniscrews: an experimental campaign on primary stability and bone properties.

نویسندگان

  • Marco Migliorati
  • Sara Drago
  • Irene Schiavetti
  • Francesco Olivero
  • Fabrizio Barberis
  • Alberto Lagazzo
  • Marco Capurro
  • Armando Silvestrini-Biavati
  • Stefano Benedicenti
چکیده

OBJECTIVE To evaluate the primary stability of different shaped miniscrews through the acquisition of data regarding maximum insertion torque, pullout force, and a radiodiagnosic evaluation of bone characteristics. MATERIALS AND METHODS Sixty fresh porcine bone samples were scanned by computed tomography (CT) and cone-beam computed tomography (CBCT). By means of a dedicated software, CT and CBCT images were analysed to measure the insertion-site cortical thickness, cortical density, and marrow bone density. Sixty miniscrews of 12 different types were implanted with no predrilling pilot hole in the bone samples. Every device was tightened by means of a digital torque screwdriver and torque data were collected. Subsequently, pullout tests were performed. Spearman and Pearson correlations were employed to compare any relationship between continuous variables. RESULTS Different types of miniscrews did not show statistically significant differences in their torque value (P = 0.595), instead a significant difference was revealed by considering their load measures (P = 0.039). Cortical bone thickness resulted strongly correlated both with value of load (P < 0.001), and modestly with torque measures (P = 0.004). A strong positive correlation was found between CT and CBCT both for cortical density (P < 0.001) and marrow bone density (P < 0.001). CONCLUSION Bone characteristics play the major role in miniscrews primary stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

Evaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study

BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this stu...

متن کامل

The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study.

The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability. In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil ...

متن کامل

Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews – an in vitro study

BACKGROUND The aim of the present study was to evaluate the relationship between insertion torque and stability of miniscrews in terms of resistance against dislocation, then comparing a self-tapping screw with a self-drilling one. METHODS Insertion torque was measured during placement of 30 self-drilling and 31 self-tapping stainless steel miniscrews (Leone SpA, Sesto Fiorentino, Italy) in s...

متن کامل

Enhanced compatibility and initial stability of Ti6Al4V alloy orthodontic miniscrews subjected to anodization, cyclic precalcification, and heat treatment

OBJECTIVE To evaluate the bioactivity, and the biomechanical and bone-regenerative properties of Ti6Al4V miniscrews subjected to anodization, cyclic precalcification, and heat treatment (APH treatment) and their potential clinical use. METHODS The surfaces of Ti6Al4V alloys were modified by APH treatment. Bioactivity was assessed after immersion in simulated body fluid for 3 days. The hydroph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2015