Intrathoracic tracheal volume and collapsibility on inspiratory and end-expiratory ct scans correlations with lung volume and pulmonary function in 85 smokers.
نویسندگان
چکیده
RATIONALE AND OBJECTIVES To evaluate the correlations of tracheal volume and collapsibility on inspiratory and end-expiratory computed tomography (CT) with lung volume and with lung function in smokers. MATERIALS AND METHODS The institutional review board approved this study at each institution. 85 smokers (mean age 68, range 45-87 years; 40 females and 45 males) underwent pulmonary function tests and chest CT at full inspiration and end-expiration. On both scans, intrathoracic tracheal volume and lung volume were measured. Collapsibility of the trachea and the lung was expressed as expiratory/inspiratory (E/I) ratios of these volumes. Correlations of the tracheal measurements with the lung measurements and with lung function were evaluated by the linear regression analysis. RESULTS Tracheal volume showed moderate or strong, positive correlations with lung volume on both inspiratory (r = 0.661, P < .0001) and end-expiratory (r = 0.749, P < .0001) scans. The E/I ratio of tracheal volume showed a strong, positive correlation with the E/I ratio of lung volume (r = 0.711, P < .0001). A weak, negative correlation was found between the E/I ratio of tracheal volume and the ratio of forced expiratory volume in the first second to forced vital capacity (r = -0.436, P < .0001). Also, a weak, positive correlation was observed between the E/I ratio of tracheal volume and the ratio of residual volume to total lung capacity (r = 0.253, P = .02). CONCLUSIONS Tracheal volume and collapsibility, measured by inspiratory and end-expiratory CT scans, is related to lung volume and collapsibility. The highly collapsed trachea on end-expiratory CT does not indicate more severe airflow limitation or air-trapping in smokers.
منابع مشابه
Is intrathoracic tracheal collapsibility correlated to clinical phenotypes and sex in patients with COPD?
A substantial proportion of patients with chronic obstructive pulmonary disease (COPD) develops various degree of intrathoracic tracheal collapsibility. We studied whether the magnitude of intrathoracic tracheal collapsibility could be different across clinical phenotypes and sex in COPD. Intrathoracic tracheal collapsibility measured at paired inspiratory-expiratory low dose computed tomograph...
متن کاملCollapsibility of lung volume by paired inspiratory and expiratory CT scans: correlations with lung function and mean lung density.
RATIONALE AND OBJECTIVES To evaluate the relationship between measurements of lung volume (LV) on inspiratory/expiratory computed tomography (CT) scans, pulmonary function tests (PFT), and CT measurements of emphysema in individuals with chronic obstructive pulmonary disease. MATERIALS AND METHODS Forty-six smokers (20 females and 26 males; age range 46-81 years), enrolled in the Lung Tissue ...
متن کاملQuantitative Computed Tomography Measurement of Tracheal Cross-Sectional Areas in Relapsing Polychondritis: Correlations with Spirometric Values.
BACKGROUND Although tracheal stenosis occurs in relapsing polychondritis (RP), no studies exist that have clarified correlations between quantitative airway measurement and spirometry in RP patients. OBJECTIVES The aim of this study was to investigate correlations between the cross-sectional area (CSA) of the trachea and spirometric values in patients with RP. METHODS The institutional revi...
متن کاملLobar analysis of collapsibility indices to assess functional lung volumes in COPD patients
BACKGROUND We investigated correlations between lung volume collapsibility indices and pulmonary function test (PFT) results and assessed lobar differences in chronic obstructive pulmonary disease (COPD) patients, using paired inspiratory and expiratory three dimensional (3D) computed tomography (CT) images. METHODS We retrospectively assessed 28 COPD patients who underwent paired inspiratory...
متن کاملKurtosis and skewness of density histograms on inspiratory and expiratory CT scans in smokers.
The aim of this study is to evaluate the relationship between lung function and kurtosis or skewness of lung density histograms on computed tomography (CT) in smokers. Forty-six smokers (age range 46?81 years), enrolled in the Lung Tissue Research Consortium, underwent pulmonary function tests (PFT) and chest CT at full inspiration and full expiration. On both inspiratory and expiratory scans, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Academic radiology
دوره 18 3 شماره
صفحات -
تاریخ انتشار 2011