Novel technique for removal of a broken intracortical screw during THA.
نویسندگان
چکیده
Most reports regarding hardware removal involve the violation of the cortex to allow a specialized to tool to extract a retained fragment. This leaves large, unfilled screw holes that act as stress risers for months postoperatively. This article describes a novel technique to remove a retained intracortical screw fragment during total hip arthroplasty. Conversion of an intertrochanteric osteotomy to a total hip arthroplasty can be made more difficult by anatomical changes to the femur and retained hardware. Direct access to the intramedullary canal during total hip arthroplasty allowed for the safe removal of a retained intracortical screw using this technique.
منابع مشابه
Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...
متن کاملImplant Removal Matrix for the Upper Extremity Orthopedic Surgeon
Orthopedic implant removal is a commonly performed procedure. While implant removal can be associated withimproved symptoms, risks of the surgery are notable. Stripped screws, broken and retained hardware, and morbidityassociated with soft tissue compromise during difficult removal are all common. Familiarity with the instruments iscritical to procedure success. The purpose of...
متن کاملA technique for removal of broken cannulated tricortical syndesmotic screws.
Breakage rates of tricortical syndesmotic screws after weight bearing range from 10% to 29%. Removal of the portion of the broken screw buried within the tibia often proves quite difficult. We report a new technique to remove a broken cannulated syndesmotic screw. This technique is simple, time saving, and less traumatic than previously reported methods of broken syndesmotic screw removal.
متن کاملRemoval of locking plates: new implant, new challenges and new solutions
Removal of locking plates in many ways poses novel challenges compared to conventional plates. None of the techniques described for the removal of locking plates are adequate for all situations. We report our experience of 27 patients from whom a total of 33 locking plates were removed. We also describe a novel technique for the removal of locking plates which in our experience could be used in...
متن کاملSimple Technique for Removing Broken Pedicular Screws
The procedure for removing a broken pedicle screw should ideally be technically easy and minimally invasive, as any damage to the pedicle, during removal of the broken screw, may weaken the pedicle, thus compromising on the success of re-instrumentation. We describe the case of a 32-year old man who had undergone surgery for traumatic third lumbar vertebral body fracture three years prior to cu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 36 11 شماره
صفحات -
تاریخ انتشار 2013