Relation between shock-related myocardial injury and defibrillation efficacy of monophasic and biphasic shocks in a canine model.

نویسندگان

  • S Osswald
  • T G Trouton
  • S S O'Nunain
  • H B Holden
  • J N Ruskin
  • H Garan
چکیده

BACKGROUND Certain biphasic waveforms with specific time ratios of positive and negative components require less energy for successful defibrillation of the fibrillating ventricles than monophasic waveforms. However, if more efficient waveforms were also to be associated with more injurious effects on myocardial function, they might not provide a true biological advantage. This study investigates the relation between defibrillation efficacy and potential toxicity of monophasic and asymmetric, single capacitor, biphasic waveforms with equal durations of positive and negative components. METHODS AND RESULTS The myocardial lactate extraction rate (LER) was used to measure the injurious effects on myocardial oxidative metabolism of two synchronized 35-J shocks in sinus rhythm. LER, mean arterial pressure (MAP) and, in a subset of experiments, cardiac output (CO) and coronary blood flow (CBF) were measured at baseline, 30 seconds, 60 seconds, 90 seconds, 150 seconds, 300 seconds, and 600 seconds after the shocks. In 12 dogs, three different waveforms (M 10: monophasic 10 milliseconds; BI 10: biphasic 10 milliseconds; BI 20: biphasic 20 milliseconds) were tested as series of two consecutive shocks (60 seconds apart) resulting in a total of 36 sets of data. At baseline, LER was 25 +/- 11%. After monophasic shocks, LER decreased significantly more than after biphasic shocks (LER at 150 seconds: M 10: -6 +/- 31% versus BI 10: 21 +/- 15% versus BI 20: 21 +/- 16%; M 10 versus BI 10 and M 10 versus BI 20, P < .05) and showed also a slower recovery (LER at 300 seconds: M 10: 1 +/- 24% versus BI 10: 20 +/- 11% versus BI 20: 20 +/- 15%; M 10 versus BI 10 and M 10 versus BI 20, P < .05). The maximal decrease in LER was 41 +/- 27% for M 10 compared with 18 +/- 15% for BI 10 and 15 +/- 11% for BI 20 (both, M 10 versus BI 10 and M 10 versus BI 20, P < .05). There was a similar decrease in CO and MAP, with the lowest MAP after monophasic shocks. The maximal decrease in MAP was significantly greater after M 10 compared with BI 20 (-29 +/- 15 mm Hg versus -13 +/- 11 mm Hg, P < .05). The defibrillation threshold was 18.6 +/- 8 J for M 10 compared with 11.5 +/- 4.0 J for BI 10 (P < .05) and 15.0 +/- 6.1 J for BI 20, respectively (P = NS). CONCLUSIONS Our results suggest that these specific biphasic waveforms are associated with less injurious effects on myocardial oxidative metabolism and hemodynamic performance. Given their higher defibrillation efficacy as well, biphasic waveforms may provide important long-term benefits in patients receiving frequent shocks from implantable cardioverter-defibrillators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disparate effects of biphasic and monophasic shocks on postshock refractory period dispersion.

The magnitude by which a defibrillation shock extends the refractory period immediately postshock (refractory period extension, RPE) does not explain why biphasic shocks defibrillate with greater efficacy than monophasic shocks. It may be that spatial heterogeneity of RPE is a more important regulator of defibrillation efficacy. We measured RPE in 15 pentobarbital-anesthetized swine using 400-V...

متن کامل

Relation of atrial refractoriness to upper and lower limits of vulnerability for atrial fibrillation/flutter following implantable ventricular defibrillator shocks.

BACKGROUND Implantable ventricular cardioverter defibrillator (ICD) shocks can cause atrial fibrillation/flutter (AF). This study investigated the pathogenesis of AF after ICD shocks in a canine model. METHODS AND RESULTS The study was conducted in 8 dogs. In 5 dogs (group 1), truncated exponential (8 ms, 78% tilt) monophasic and biphasic shocks were delivered through a bipolar epicardial (pa...

متن کامل

Comparing the efficacy and safety of a novel monophasic waveform delivered by the passive implantable atrial defibrillator with biphasic waveforms in cardioversion of atrial fibrillation.

BACKGROUND The passive implantable atrial defibrillator (PIAD) (with no battery or discharging capacitor and powered transcutaneously by radio-frequency energy) delivering a novel monophasic low-tilt waveform is more efficacious than the standard monophasic waveform at atrial defibrillation. Standard biphasic (STB) waveforms, however, are more efficacious and safer than monophasic waveforms. Th...

متن کامل

Comparison of a novel rectilinear biphasic waveform with a damped sine wave monophasic waveform for transthoracic ventricular defibrillation. ZOLL Investigators.

OBJECTIVES We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND Multiple studies have shown that for endocardial defibrillation, biphasic waveforms have a greater efficacy than monophasic waveforms. More recently, a 130-J truncated exponential...

متن کامل

Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system.

Electrode polarity has been reported to be one of the factors that affect defibrillation efficacy. We studied the influence of polarity on defibrillation efficacy when monophasic and biphasic waveforms were used with an endocardial lead system. In six anesthetized pigs, defibrillation catheters were placed in the right ventricular (RV) apex and at the junction of the superior vena cava (SVC) an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 90 5  شماره 

صفحات  -

تاریخ انتشار 1994