Reliability and interpretation of single leg stance and maximum voluntary isometric contraction methods of electromyography normalization.

نویسندگان

  • Marc F Norcross
  • J Troy Blackburn
  • Benjamin M Goerger
چکیده

Normalization of electromyographic (EMG) amplitudes is necessary in the study of human motion. However, there is a lack of agreement on the most reliable and appropriate normalization method. This study evaluated the reliability of single leg stance (SLS) and maximal voluntary isometric contraction (MVIC) normalization methods and the relationship between these measures for the gluteus maximus (GMax), gluteus medius (GMed), rectus femoris (RF), vastus lateralis (VL), hip adductor group (ADD), and biceps femoris (BF). Surface EMG was recorded in 20 subjects during three 5s trials of SLS and MVIC. SLS and MVIC methods both demonstrated good-to-excellent reliability in all muscles (ICCs>0.80). Intrasubject coefficients of variation were lower for the MVIC method (9-36%) than for the SLS method (20-59%). EMG amplitudes during MVIC and SLS were significantly correlated for all muscles (Pearson r's=0.604-0.905, p<0.005) except GMax (r=0.250, p=0.288). Use of SLS normalization for the RF, VL, and BF is not recommended due to a lack of measurement precision. However, this method is justified in the GMax, GMed, and ADD and may provide a better representation of coordinated muscle function during a functional task.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Ankle Brace on the Activity and Co-Contraction of Ankle Muscles During Single-Leg Landing

Objectives: The results of a few studies about the effects of ankle brace on muscles function during the performance of different tasks are contradictory. Moreover, the effect of brace on the co-contraction of ankle muscles is undiscovered. Therefore, the present study investigated the effect of brace usage on the ankle muscles activity and co-contraction during single-leg landing. Methods: Fi...

متن کامل

Comparison of maximum voluntary isometric contraction of the biceps on various posture and respiration conditions for normalization of electromyography data

[Purpose] Maximum voluntary isometric contraction can increase the reliability of electromyography data by controlling respiration; however, many studies that use normalization of electromyography data fail to account for this. This study aims to check changes in maximum voluntary isometric contraction based on changes in posture and respiration conditions. [Subjects and Methods] Twenty-two hea...

متن کامل

Reliability of electromyographic normalization methods for evaluating the hip musculature.

The purpose of this study was to determine the reliability of three normalization methods for analyzing hip abductor activation during rehabilitation exercises. Thirteen healthy subjects performed three open kinetic chain and three closed kinetic chain hip abductor exercises. Surface EMG activity for the gluteus medius was collected during each exercise and normalized based on a maximum volunta...

متن کامل

An alternative test of electromyographic normalization in patients.

The value of electromyography (EMG) in the interpretation of normal and pathological movement depends on recording, processing, and normalization procedures. Traditionally, maximum voluntary isometric contraction (MVIC) of individual muscles is commonly used for EMG normalization. However, this is a time- and energy-consuming procedure, especially in patients. The aim of the present study was t...

متن کامل

A Reliability of Electromyographic Normalization Methods for the Infraspinatus Muscle in Healthy Subjects

The purpose of this study was to examine the test-retest reliability of normalization methods for the infraspinatus muscle in a group of healthy subjects. Twelve healthy subjects (male=8, female=4) performed the maximal voluntary isometric contraction (MVIC) with examiner`s resistance, MVIC with a digital tension-meter (MVIC-DT), and sub-MVIC methods. Surface electromyography (EMG) signals were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2010