Trans-Fontan baffle placement of an endocardial systemic ventricular pacing lead

نویسندگان

  • Elizabeth DeWitt
  • Ryan Callahan
  • Elizabeth Blume
  • Audrey Marshall
  • Douglas Mah
چکیده

Introduction Patients with single-ventricle physiology palliated to a Fontan can be at risk for high-grade atrioventricular block, necessitating permanent pacemaker placement. Historically, epicardial leads have been used for these patients given the concern for clot formation within the Fontan pathway or systemic ventricle. However, epicardial pacing systems are fraught with issues, including higher pacing thresholds and increased risk for lead failure. Given this, transvenous leads are being used more routinely for atrial pacing, with some case reports even reporting atrial leads within the pulmonary venous atrium. This is the first report of a transvenous ventricular lead in a Fontan patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Targeted left ventricular endocardial pacing using a steerable introducing guide catheter and active fixation pacing lead.

AIMS Cardiac resynchronization therapy via the coronary sinus (CS) is not always possible. Left ventricular (LV) endocardial lead placement is a potential alternative. The purpose of this study was to assess the feasibility of endocardial LV pacing using a steerable lead introducer and active fixation polyurethane lead. METHODS AND RESULTS Endocardial LV lead placement was attempted in nine p...

متن کامل

Inadvertent placement of pacemaker lead into the systemic ventricle in repaired D-transposition of the great arteries.

We report a case of a 27-year-old man with Senning repair of D-transposition of the great arteries. A dual-chamber pacemaker was placed for syncope due to sinoatrial node dysfunction 3 years before this presentation. He had no further syncope but complained of dyspnea on exertion and mild exercise intolerance. A routine chest x-ray and transthoracic echocardiography suggested the presence of a ...

متن کامل

Direct visualization of an atrial transseptal left ventricular endocardial lead implantation within an isolated heart

Introduction Left ventricular (LV) endocardial pacing is a relatively new therapy that may offer several advantages over coronary venous lead placement for biventricular resynchronization therapy, including access to more regions of the LV, faster impulse propagation, avoidance of phrenic nerve stimulation, and more physiologic LV activation. We report a case of transseptal implantation of a pa...

متن کامل

Is the extracardiac conduit the preferred Fontan approach for patients with univentricular hearts? The extracardiac conduit is the preferred Fontan approach for patients with univentricular hearts.

Fontan palliation for single-ventricle patients was first described in 1971.1 The original approach was in the form of a classic atriopulmonary Fontan connection, bypassing the nonfunctional right ventricle. After recognizing the long-term complication of an atriopulmonary connection (right atrial dilation, arrhythmias, and thrombus formation), modifications have been made. The atriopulmonary c...

متن کامل

Transcatheter closure of fontan fenestrations using the Amplatzer septal occluder: initial experience and follow-up.

We have recently used the Amplatzer septal occluder to close Fontan fenestrations. Between June 1998 and December 1999, 13 patients underwent transcatheter occlusion of their Fontan fenestrations. Systemic blood flow decreased significantly without a concomitant decrease in pulmonary blood flow. All residual shunts detectable by oximetry were at sites separate from those into which occlusion de...