Comparison of hyperemic efficacy between central and peripheral venous adenosine infusion for fractional flow reserve measurement.

نویسندگان

  • Myung-Ki Seo
  • Bon-Kwon Koo
  • Ji-Hyun Kim
  • Dong-Ho Shin
  • Han-Mo Yang
  • Kyung-Woo Park
  • Hae-Young Lee
  • Hyun-Jae Kang
  • Hyo-Soo Kim
  • Byung-Hee Oh
  • Young-Bae Park
چکیده

BACKGROUND Maximal hyperemia is a prerequisite for the accurate measurement of fractional flow reserve (FFR). Although continuous infusion of adenosine via the femoral vein is considered to be the gold standard, this requires an additional invasive procedure for femoral vein access and is difficult to use during transradial coronary catheterization. We performed this prospective study to evaluate the feasibility and efficacy of peripheral intravenous infusion of adenosine for FFR measurement. METHODS AND RESULTS Seventy-one patients were prospectively enrolled, and FFR was measured using a 0.014-inch coronary pressure wire. Hyperemic efficacy of adenosine was compared among intracoronary bolus injection and continuous IV infusion (140 μg/min/kg) via the femoral and via the forearm vein. In 20 patients, hyperemic mean transit time and index of microcirculatory resistance were also measured. Mean FFR after bolus administration of adenosine was 0.81±0.10. As compared with femoral vein infusion (FFR: 0.80±0.10), hyperemic efficacy of forearm vein infusion of adenosine (FFR: 0.80±0.11) was not inferior (P for noninferiority=0.01). The number of functionally significant stenoses (FFR <0.75) was also not different between the 2 methods (femoral vein versus forearm vein; 17 (25.0%) versus 17 (25.0%), P=1.0). Both hyperemic mean transit time and index of microcirculatory resistance were not different between the 2 routes of adenosine infusion. Additional bolus injection of adenosine during IV infusion did not improve the hyperemic efficacy but increased the risk of atrioventricular block. CONCLUSIONS This study suggests that continuous intravenous infusion of adenosine via the forearm vein is a convenient and effective way to induce steady-state hyperemia for invasive physiological measurements. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01070420.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracoronary continuous adenosine infusion.

BACKGROUND Various methods are used to induce maximal hyperemia for physiologic studies, but the feasibility and efficacy of continuous intracoronary (IC) infusion of adenosine for measurement of fractional flow reserve (FFR) has not been well-defined. METHODS AND RESULTS Patients with intermediate coronary artery stenosis were consecutively enrolled. In the phase I study, FFR was measured af...

متن کامل

End-diastolic fractional flow reserve: comparison with conventional full-cardiac cycle fractional flow reserve.

BACKGROUND Diastolic fractional flow reserve (dFFR) has been shown to be highly sensitive for detection of inducible myocardial ischemia. However, its reliance on measurement of left-ventricular pressure for zero-flow pressure correction, as well as manual extraction of the diastolic interval, has been its major limitation. Given previous reports of minimal zero-flow pressure at end-diastole, w...

متن کامل

The diastolic hyperemic flow versus pressure relation. A new index of coronary stenosis severity and flow reserve.

The measurement of coronary flow reserve, traditionally calculated as the ratio of maximal hyperemic blood flow divided by basal flow, is difficult to interpret in serial studies because fluctuating hemodynamic parameters may affect either basal or hyperemic flow measurements. To determine the magnitude of this problem and to develop alternative approaches for measuring vascular reserve, 10 ane...

متن کامل

Low coronary microcirculatory resistance associated with profound hypotension during intravenous adenosine infusion: implications for the functional assessment of coronary stenoses.

BACKGROUND Intravenous adenosine infusion produces coronary and systemic vasodilatation, generally leading to systemic hypotension. However, adenosine-induced hypotension during stable hyperemia is heterogeneous, and its relevance to coronary stenoses assessment with fractional flow reserve (FFR) remains largely unknown. METHODS AND RESULTS FFR, coronary flow reserve, and index of microcircul...

متن کامل

The Diastolic Hyperemic Flow Versus Pressure Relation A New Index of Coronary Stenosis Severity and Flow Reserve

The measurement of coronary flow reserve, traditionally calculated as the ratio of maximal hyperemic blood flow divided by basal flow, is difficult to interpret in serial studies because fluctuating hemodynamic parameters may affect either basal or hyperemic flow measurements. To determine the magnitude of this problem and to develop alternative approaches for measuring vascular reserve, 10 ane...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2012