Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file.
نویسندگان
چکیده
INTRODUCTION The purpose of this study was to compare dentinal microcrack formation while using hand files (HFs), 4 brands of nickel-titanium (NiTi) rotary files and the self-adjusting file. METHODS One hundred forty mandibular first molars were selected: 20 teeth were left unprepared and served as control, and the remaining 120 teeth were divided into 6 groups. HFs, HERO Shaper (HS; Micro-Mega, Besancon, France), Revo-S (RS, Micro-Mega), Twisted File (TF; SybronEndo, Orange, CA), ProTaper (PT, Dentsply Maillefer), and SAFs were used to prepare the 2 mesial canals. Roots were then sectioned 3, 6, and 9 mm from the apex, and the cut surface was observed under a microscope and checked for the presence of dentinal microcracks. RESULTS The control, HF, and SAF groups did not show any microcracks. In roots prepared with the HS, RS, TF, and PT, dentinal microcracks were observed in 60%, 25%, 44%, and 30% of teeth, respectively. There was a significant difference between the control/HF/SAF group and the 4 NiTi rotary instrument groups (P < .0001). However, no significant difference was found among the 4 NiTi rotary instruments (P > .005). CONCLUSIONS All rotary files created microcracks in the root dentin, whereas the SAF file and hand instrumentation presented with satisfactory results with no dentinal microcracks.
منابع مشابه
In-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation
Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having ...
متن کاملIn Vitro Evaluation of Dentinal Microcrack Formation during Root Canal Preparations by Different Niti Systems
The purpose of this study was to compare dentinal microcrack formation while using hand ProTaper (PT), ProTaper and ProTaper Next rotary files. Forty single rooted teeth were selected. 10 teeth were left unprepared and served as control, and the remaining 30 teeth were divided into 3 groups. After preparation with the file system selected, roots were sectioned 3, 6, and 9 mm from the apex, and ...
متن کاملComparative Evaluation of Dentinal Microcrack Incidence After Root Canal Preparation by BioRaCe and Edge Taper Platinum
Background and Aim: Preparation of root canal with rotary nickel-titanium (NiTi) instruments may potentially create microcracks that can lead to vertical root fracture. This study aimed to compare the incidence of crack formation by BioRaCe and Edge Taper Platinum systems in the mesiobuccal canals of extracted first mandibular molars. Materials and Methods: In this experimental study, 50 first...
متن کاملResearch Paper: Comparison efficacy of calcium hydroxide removal by Revo-s, Protaper Rotary file from root canal
Abstract Introduction: The aim of this study was to evaluate the efficacy of two rotary instrument systems (ProTaper and Revo-s File) in removing calcium hydroxide residues from root canal walls Materials and Methods:Thirty human maxillary incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl,and filled with a calcium hydroxide intracanal dr...
متن کاملEffect of different nickel-titanium rotary files on dentinal crack formation during retreatment procedure
Background. The aim of this study was to compare the dentinal defects caused by Reciproc, TF Adaptive and ProTaper Next NiTi rotary file systems during the retreatment procedure. Methods. A total of 150 mandibular incisors with straight and single root canals were included in the present study. All the root canals were prepared up to an apical diameter 0.40 mm using stainless steel files. Thirt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال: