Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter

نویسندگان

  • Fulai Peng
  • Zhengbo Zhang
  • Xiaoming Gou
  • Hongyun Liu
  • Weidong Wang
چکیده

BACKGROUND The calculation of arterial oxygen saturation (SpO2) relies heavily on the amplitude information of the high-quality photoplethysmographic (PPG) signals, which could be contaminated by motion artifacts (MA) during monitoring. METHODS A new method combining temporally constrained independent component analysis (cICA) and adaptive filters is presented here to extract the clean PPG signals from the MA corrupted PPG signals with the amplitude information reserved. The underlying PPG signal could be extracted from the MA contaminated PPG signals automatically by using cICA algorithm. Then the amplitude information of the PPG signals could be recovered by using adaptive filters. RESULTS Compared with conventional ICA algorithms, the proposed approach is permutation and scale ambiguity-free. Numerical examples with both synthetic datasets and real-world MA corrupted PPG signals demonstrate that the proposed method could remove the MA from MA contaminated PPG signals more effectively than the two existing FFT-LMS and moving average filter (MAF) methods. CONCLUSIONS This paper presents a new method which combines the cICA algorithm and adaptive filter to extract the underlying PPG signals from the MA contaminated PPG signals with the amplitude information reserved. The new method could be used in the situations where one wants to extract the interested source automatically from the mixed observed signals with the amplitude information reserved. The results of study demonstrated the efficacy of this proposed method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

ECG Artifact Removal from Surface EMG Signal Using an Automated Method Based on Wavelet-ICA

This study aims at proposing an efficient method for automated electrocardiography (ECG) artifact removal from surface electromyography (EMG) signals recorded from upper trunk muscles. Wavelet transform is applied to the simulated data set of corrupted surface EMG signals to create multidimensional signal. Afterward, independent component analysis (ICA) is used to separate ECG artifact componen...

متن کامل

Eye Blinks Removal in Single-channel Eeg Using Savitzky-golay Referenced Adaptive Filtering: a Comparison with Independent Component Analysis Method

Eye blink artifact is one of the major problems in electroencephalograph (EEG) signals which mainly affected a frontal channel. A frontal channel often involved in recent applications of portable EEG devices which require a real time processing including for artifact removal. In this paper, we proposed a new referencing method in adaptive filtering for eye blinks removal of a single-channel EEG...

متن کامل

Design of AS-LMS Adaptive filter for reduction of Motion Artifacts in PPG signals

This paper proposes a simple and efficient approach for reducing Motion Artifact (MA) in corrupted PPG (Photo Plethysmo Graphic) Signals based on AS-LMS Adaptive Filter. The performance of pulse oximeters is highly influenced by motion artifact in PPG signals. To generate the noise reference signal for an adaptive filtering process, instead of using any additional hardware such as accelerometer...

متن کامل

Proposing Combined Approaches to Remove Ecg Artifacts from Surface Emg Signals

Electromyography (EMG) is a tool routinely used for a variety of applications in a very large breadth of disciplines. However, this signal is inevitably contaminated by various artifacts originated from different sources. Electrical activity of heart muscles, electrocardiogram (ECG), is one of sources which affects the EMG signals due to the proximity of the collection sites to the heart and ma...