Visual Function Assessment in Medical Imaging Research.

نویسندگان

  • Carla Lança
  • John D Thompson
  • Luis Lança
  • Peter Hogg
چکیده

BACKGROUND Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. METHODS Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. RESULTS Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. CONCLUSION All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Bayesian approach for image denoising in MRI

Magnetic Resonance Imaging (MRI) is a notable medical imaging technique that is based on Nuclear Magnetic Resonance (NMR). MRI is a safe imaging method with high contrast between soft tissues, which made it the most popular imaging technique in clinical applications. MR Imagechr('39')s visual quality plays a vital role in medical diagnostics that can be severely corrupted by existing noise duri...

متن کامل

Assessment of deconvolution technique for diagnosis of hydronephrosis in infants (under 6 months) [persian]

Introduction: Hydronephrosis is one of the major causes of referring infants for nuclear medicine investigation. Renal dynamic study is the most reliable investigation for such children. However direct evaluation of renogram leads to generation of parameters that have no physiological interpretation. The configuration of renogram is very much dependent upon the rate at which radiopharmace...

متن کامل

ASSESSMENT OF PHYSICAL FUNCTIONING AND ITS CORRELATES IN ADULTS 50 YEARS AND OLDER IN BUKAN, NORTHWEST OF IRAN; A CROSS-SECTIONAL STUDY

Background & Aims: Aging is associated with gradual erosive changes in the physiological function of many systems of the body. Ths study aimed to examine the physical functioning and limitation and its related factors in people aged 50 and older in Bukan, 2017. Materials & Methods: In this cross-sectional study 1201 elderly people aged 50 years and up were recruited from health recentres in Bu...

متن کامل

Assessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques

The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...

متن کامل

Repeatability of Detecting Visual Cortex Activity in Functional Magnetic Resonance Imaging

Introduction As functional magnetic resonance imaging (fMRI) is too expensive and time consuming, its frequent implementation is difficult. The aim of this study is to evaluate repeatability of detecting visual cortex activity in fMRI. Materials and Methods In this study, 15 normal volunteers (10 female, 5 male; Mean age±SD: 24.7±3.8 years) attended. Functional magnetic resonance images were ob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiologic technology

دوره 87 2  شماره 

صفحات  -

تاریخ انتشار 2015