Myocardial T1 mapping and determination of partition coefficients at 3 tesla: comparison between gadobenate dimeglumine and gadofosveset trisodium
نویسندگان
چکیده
Objective To compare an albumin-bound gadolinium chelate (gadofosveset trisodium) and an extracellular contrast agent (gadobenate dimeglumine), in terms of their effects on myocardial longitudinal (T1) relaxation time and partition coefficient. Materials and Methods Study subjects underwent two imaging sessions for T1 mapping at 3 tesla with a modified look-locker inversion recovery (MOLLI) pulse sequence to obtain one pre-contrast T1 map and two post-contrast T1 maps (mean 15 and 21 min, respectively). The partition coefficient was calculated as ΔR1myocardium /ΔR1blood , where R1 is 1/T1. Results A total of 252 myocardial and blood pool T1 values were obtained in 21 healthy subjects. After gadolinium administration, the myocardial T1 was longer for gadofosveset than for gadobenate, the mean difference between the two contrast agents being -7.6 ± 60 ms (p = 0.41). The inverse was true for the blood pool T1, which was longer for gadobenate than for gadofosveset, the mean difference being 56.5 ± 67 ms (p < 0.001). The partition coefficient (λ) was higher for gadobenate than gadofosveset (0.41 vs. 0.33), indicating slower blood pool washout for gadofosveset than for gadobenate. Conclusion Myocardial T1 times did not differ significantly between gadobenate and gadofosveset. At typical clinical doses of the contrast agents, partition coefficients were significantly lower for the intravascular contrast agent than for the extravascular agent.
منابع مشابه
A Comparison between Gadofosveset Trisodium and Gadobenate Dimeglumine for Steady State MRA of the Thoracic Vasculature
PURPOSE Retrospective comparison between gadofosveset trisodium and gadobenate dimeglumine steady state magnetic resonance angiography (SS-MRA) of the thoracic vasculature at 1.5T using signal-to-noise ratio (SNR) and vessel edge sharpness (ES) as markers of image quality. MATERIALS AND METHODS IRB approval was obtained. Twenty separate patients each underwent SS-MRA using high-resolution 3D ...
متن کاملSample size calculation for clinical trials using cardiac magnetic resonance partition coefficient and extracellular volume fraction for the assessment of diffuse myocardial fibrosis
Methods A modified Look-Locker with inversion recovery (MOLLI) sequence was used to determine myocardial T1 values pre-, and 12 and 25 min post-administration of a gadolinium-based contrast agent at 3 Tesla. For 24 healthy subjects (8 men; 29±6 years), two separate scans were obtained a) with a bolus of 0.15 mmol/kg of gadopentate dimeglumine and b) 0.1 mmol/kg of gadobenate dimeglumine, respec...
متن کاملDiffuse myocardial fibrosis evaluation using cardiac magnetic resonance T1 mapping: sample size considerations for clinical trials
BACKGROUND Cardiac magnetic resonance (CMR) T1 mapping has been used to characterize myocardial diffuse fibrosis. The aim of this study is to determine the reproducibility and sample size of CMR fibrosis measurements that would be applicable in clinical trials. METHODS A modified Look-Locker with inversion recovery (MOLLI) sequence was used to determine myocardial T1 values pre-, and 12 and 2...
متن کاملCMR myocardial infarct evaluation in a canine model by three different contrast agents
We evaluated R1 curves, CNR and scar visualization and quantification in a dog model of myocardial infarction by CMR, using three different contrast agents: Gadopentate dimeglumine (Gd-DTPA, Magnevist), Gadobenate dimeglumine (Gd-BOPTA, MultiHance), and Gadofosveset (Ablavar). Gd-DTPA showed better characteristics for myocardial scar visualization and quantification. Gadofosveset demonstrated l...
متن کاملThe protein binding substance Ibuprofen does not affect the T1 time or partition coefficient in contrast-enhanced cardiovascular magnetic resonance
BACKGROUND Contrast enhanced cardiovascular magnetic resonance (CMR) with T1 mapping enables quantification of diffuse myocardial fibrosis. Various factors, however, can interfere with T1 measurements. The purpose of the current study was to assess the effect of co-medication with a typical protein binding drug (ibuprofen) on T1 values in vitro and in vivo. METHODS 50 vials were prepared with...
متن کامل