Micro Gas Chromatography for Liquid Petroleum Gas's

ثبت نشده
چکیده

For years, microGC analysis has been useful as a powerful tool for the fast and reliable analyses of natural gas and other gaseous matrices; but, it is yet to prove its capabilities for liquid samples. In this paper, we present a unique gasifying system for volatile liquid sample introduction in a microGC. The system has been tested with a wide range of different samples: liquefied gases (ethane/propane blends, volatile liquids (natural gasoline from fractionation plants), butane blends and samples with olefins and C6+’s. Due to the different nature of the samples, a single point calibration was used. The system was designed for simple operation and maintenance, reducing time and increasing ease of operation when compared to regular Gas Chromatography analyses. All the samples were handled in the same way with the only variation being the response factors applied to each type of sample. Repeatability data will be presented from both calibration standard blends and from real world samples. Also presented are comparisons of the microGC results with conventional GC data. INTRODUCTION Natural gas, refinery gas and liquefied petroleum gas (LPG) compositions can be determined using gas chromatography. A wide range of physical properties such as heating value, specific gravity (or density), compressibility, and Wobbe index can be calculated from composition data. Those parameters play an important role in the varied applications of the natural-gas industry because they are of critical importance in determining the commercial value of the natural gas, either purchased or sold, especially in custody transfer situations. They are also particularly important for large volume end users, since even small differences in the calculated values can have a significant financial impact. Those complex samples are often analyzed using conventional multi-column, multi-valved gas chromatographs. However, fast and accurate measurement of the composition can be achieved using a Micro-GC. The micro GC is a chip-based instrument with an integrated TCD (Thermal Conductivity Detector) and independent GC cartridges, containing an injector, detector, column and heating capability up to 180°C. Its miniaturized hardware, low thermal mass, extremely accurate micro liter peak injection and short columns enable fast accurate detection while lowering costs. A complete analysis is made possible without valves and in a fraction of the time required with a conventional GC. The compact system analyzes complex gas samples using the selectivity of independent GC channels. Each GC channel, with a different column phase, simultaneously separates a different subset of sample components. Micro GC usually focuses on natural gas and process applications, (e.g., a BTU analysis is done in less than 20 seconds). When dealing with pressurized liquid samples the situation changes and sample introduction becomes a critical factor since the instrument has severe inlet pressure limitations. Finding an inlet system suitable for a wide range of sample has become a difficult task. This article shows the results obtained using a new sample introduction device (SID) designed and tested to work with any micro GC. THE ANALYSIS All QC laboratories are always looking for fast and reliable ways to analyze samples. This is also the case of Fractionation Plants QC Labs and process control. Conventional GC analysis ranged from 15 to 60 min without considering oven’s cool-down time. Micro GC is capable to make the analysis faster, however: microGC analysis has been extensively used in NG analyses but not as much for pressurized liquids. microGC needs the sample in vapor state. microGC has inlet pressure limitations. Then, it cannot be used for all types of samples unless a sample introduction system allows us to do that. There are several vaporizer regulators in the market and all are based in the same principle. A known vaporizer regulator was tested with poor results in terms of memory effects and reproducibility when dealing with pressurized liquids. A Sample Introduction Device (SID) has been designed and tested to meet the requirements of a wide range of different samples from C1 to C4 blends containing Perm Gases, olefins and C6+’s. Tailored methods for each type of sample were also tested and optimized. Due to the nature of each sample, a single point calibration for each type of sample was determined to be the most convenient way for sample quantification. The SID has a vaporizer regulator working continuously and online at fixed and constant temperature and outlet pressure. At a fixed T & P the sample will eventually reach Liquid  Vapor equilibrium within the system. THE SAMPLE We seldom deal with pure samples, usually sample are mixtures of different components (A, B, C,...n) in different proportions (X): XAA+XBB+XCC...Xnn In vapor state, sample composition not only depends on several intrinsic properties like boiling point, vapor pressure, density, molecular weight; but also on some external conditions like temperature, pressure, volume, etc. So the sample’s vapor phase composition can be expressed as a function of these properties: f (T,P,Bp,Vp...)= X v AA+X v BB+X v CC+...X v nn Then, as long as the variables are kept constant the sample will eventually reach liquid-vapor equilibrium. This is what is called a “steady state” X L AA+X L BB+X L CC...X L nn X v AA+X v BB+X v CC+...X v nn External parameters can be controlled Inlet Pressure: Sample and Standards pistons must be kept at constant P. Outlet Pressure: SID is set at a fixed outlet pressure Time: Time events are set and fixed through the SID electronics and through the Chromatographic Data Software (CDS) Temperature: SID is set at fixed T, lines are insulated, microGC components at fixed T System volume: System geometry is kept constant. Injection volume: Determined and fixed by the software. MATERIALS A system schematics is shown in Fig. 1. The SID has different mechanical and electronic components and it is designed for samples contained in constant pressure cylinders. V3 is a 3 way valve (Swagelok Co.) used for blank injections only. V1 is a 3 port-2 position valve (Valco Instruments Co. Inc) which selects between the sample and a He source used for blank injections and cleaning the system path. The gasifier is a vaporizing regulator (Controls Corporation of America) which is set at a fixed temperature (250F) and outlet pressure (6psi). Figure 1. System schematics Between the vaporizing regulator and the microGC there are 2 vents. The so-called controlled vent is a narrow 1/16” tube and V2 is a 3 way solenoid valve (Valcor Engineering Corporation) which is used to flush the system either with sample or He before injection. All wetted parts and lines are stainless steel with the exception of the V1 rotor and the constant pressure cylinder connection line. The operator connects the constant pressure cylinder to the inlet line, opens the cylinder’s valve and starts the SID. After an equilibration time (3 min), the SID indicates when the system is ready. The operator starts injecting sample into the microGC through the CDS once the equilibrium is reached A 4 channel Varian CP-4900 Micro-GC (Varian Inc.) with backflush capabilities was used for all tests. Galaxie software was the CDS used to control chromatographic parameters. Only three channels were used for the tests. Micro GC configuration is shown in Fig. 2. Figure 2. MicroGC schematics Channel #1 has PoraPLOT U capillary column for the separation and determination of permanent gases along with Methane, CO2 and Ethane. N2, O2 and CO are determined as 1 peak (Air). Channel #2 has a Al2O3 column to separate olefins, when present. Channel #3 has a CP Sil5 column to separate hydrocarbons by boiling point up to C11. EXPERIMENTAL Figure 3 shows a chromatogram of a YGrade sample obtained from channel #3, showing components peaks up to Toluene which elutes in less than 80 sec. Figure 3. YGrade Sample (Channel #3 signal) Figure 4 shows a chromatogram of a Propylene sample obtained from channel #1. Depending on the sample (method), Propane may be quantified from the signal on channel # 1 or #4. Again, air and carbon monoxide eluted as one peak in this column. To be able to have the permanent gases separated, a MolSieve column may be installed in the 4 th channel remaining on the microGC. In this case, Propane elutes in less than 90 secs. Figure 4. Propylene sample (Channel #1 signal) Chromatogram obtained from Channel #2 for the same propylene sample is shown in Fig 5.where propylene and C4 olefins eluted in less than 30 secs. 13BD elutes just after nC5, if present. Figure 5. Propylene sample (Channel #2 signal) Repeatability test were made for different samples. Gravimetrically blended standards of EP Mix, YGrade (5% C6+), Propane, Propylene, iButane and nButane were prepared and injected. Figures 6 and 7 show a couple of examples, and the results obtained with 95% of confidence. Figure 6. EP Mix Std. Repeatability test. Figure 7. Propylene Std. Repeatability test Even though calibration curves were made using just one standard, linearity was checked and for most products a good fit was found in the samples range for each component. METHOD COMPARISON The final step was the comparison of MicroGC results with the ones obtained using a conventional GC. Gravimetrically blended standards and “real world” samples were used on this comparison. First, LPG’s gravimetrically prepared samples were injected in a Hewlett Packard 5890 GC with a Thermal Conductivity detector (TCD), calibrated for this type of samples. Figures 8 and 9 show the comparison of two “synthetic” samples, a YGrade and an EP Mix respectively. In both cases a good match was found, even for the heavy ends up to 6% Mol. Run time for conventional GC was 45 minutes including cool-down time. MicroGC’s run time was around 4 min and since it is an isothermal run, no cool-down time is needed. An additional feature when using the SID is that once the system is equilibrated with a sample there is no limit in the amount of injections that can be done for that particular sample. Figure 8. Method Comparison. YGrade Std Figure 9. Method Comparison. EP Mix Std The system was installed in a customer’s facility and samples were run simultaneously in his instrument HP 5890 (Hewlett Packard). Figure 10 shows the results obtained on each instruments for an EP Sample. Figure 9. Method comparison. EP Sample from fractionation unit

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection

A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Gas-liquid Relative Permeability Estimation in 2D Porous Media by Lattice Boltzmann Method: Low Viscosity Ratio 2D LBM Relative Permeability

This work is a primary achievement in studying the CO2 and N2–oil systems. To predict gas-liquid relative permeability curves, a Shan-Chen type multicomponent multiphase lattice Boltzmann model for two-phase flow through 2D porous media is developed. Periodic and bounce back boundary conditions are applied to the model with the Guo scheme for the external body force (i.e.,...

متن کامل

-Workshop on Challenges in Crude Evaluation with Changing Crude Scenario. APPLICATION OF CHROMATOGRAPHY IN PETROLEUM FIELD

Modern chromatography by virtue offantastic capabilities for separation, qharacterization, quantitation and fractionation has emerged as a potential analytical technique for hydrocarbon industry. Presently the gas chromatography alongwith high performance liquid chromatography coverwide range ofapplications in diversified areas including Basic and applied research. Availability of large number ...

متن کامل

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011