Aspects of 3-D Imaging by Classical Tomography for Dual Detector PEM
نویسندگان
چکیده
Images from dual detector positron emission mammography (PEM) systems are commonly reconstructed by backprojection methods of classical tomography. Characteristics of 3–D PEM images were investigated using analytic models and computer simulations, in particular depth resolution and the quality of images in the third dimension normal to the detectors. These modeling tools provide insight into the depth blurring observed in 3-D images from experimental line source and breast phantom studies acquired with detectors built using pixellated arrays of LGSO crystals. Approaches to improved 3-D breast imaging are discussed.
منابع مشابه
Employing dual frequency phase sensitive demodulation technique to improve the accuracy of voltage measurement in magnetic induction tomography and designing a labratoary prototype
Magnetic induction tomography (MIT) is a promising modality for noninvasive imaging due to its contactless technology. Being a non-contact safe imaging technique, MIT has been an appropriate method in compare to other electrical tomography. In this imaging method, a primary magnetic field is applied by excitation coils to induce eddy currents in the material to be studied and a secondary magnet...
متن کاملMolecular imaging approaches in the diagnosis of breast cancer: A systematic review and meta-analysis
Introduction:The accuracy of positron emission tomography with computed tomography (PET/CT), positron emission mammography (PEM), and breast specific-gamma imaging (BSGI) in diagnosing breast cancer has never been systematically assessed, the present systematic review was aimed to address this issue. Methods:PubMed, Scopus and EMBASE were searched for st...
متن کاملDesign of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies
Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...
متن کاملPatient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...
متن کاملAnalytical Study of the Effect of the System Geometry on Photon Sensitivity and Depth of Interaction of Positron Emission Mammography
Positron emission mammography (PEM) cameras are novel-dedicated PET systems optimized to image the breast. For these cameras it is essential to achieve an optimum trade-off between sensitivity and spatial resolution and therefore the main challenge for the novel cameras is to improve the sensitivity without degrading the spatial resolution. We carry out an analytical study of the effect of the ...