Microkeratome-assisted preparation of ultrathin grafts for descemet stripping automated endothelial keratoplasty.

نویسندگان

  • Massimo Busin
  • Amit K Patel
  • Vincenzo Scorcia
  • Diego Ponzin
چکیده

PURPOSE To compare three microkeratome-assisted techniques for the preparation of ultrathin (UT) grafts for Descemet stripping automated endothelial keratoplasty. METHODS After dissection with a 300-μm microkeratome head in 40 donor tissues, a second cut was performed with a 130-μm head either after manual stromal hydration (group A, n = 10) or osmotic hydration at the eye bank (group B, n = 10) or with a 50- or 90-μm head, depending on residual bed thickness (group C, n = 10); no further dissection was performed in the control group (group D, n = 10). Corneal thickness and endothelial cell (EC) count were determined at all appropriate stages. Statistical analysis was performed using a Fisher exact test. RESULTS Final graft thicknesses in groups A (89.1 ± 34.1μm), B (84.1 ± 18.6 μm), and C (72.1 ± 10.1 μm) were significantly lower than in group D (201.9 ± 25.3 μm) (P < 0.001). EC loss did not differ significantly among the groups. Multiple areas of Descemet detachment were seen in 4 of 10 corneas of group A. CONCLUSIONS All methods proved equally efficient in producing UT grafts, but stromal hydration induced tissue structural changes. EC loss was unaffected by the additional manipulation required to prepare UT grafts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined use of a femtosecond laser and a microkeratome in obtaining thin grafts for Descemet stripping automated endothelial keratoplasty: an eye bank study.

PURPOSE To evaluate the use of a femtosecond laser combined with a microkeratome in the preparation of posterior corneal disks for Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS This experimental study involved ultrathin DSAEK tissue preparation of 22 donor corneas unsuitable for transplantation. The first cut was performed with an Intralase® FS60 laser and the second ...

متن کامل

Femtosecond laser and microkeratome-assisted Descemet stripping endothelial keratoplasty: first clinical results.

AIM To perform Descemet stripping automated endothelial keratoplasty (DSAEK) using a novel technique to obtain very thin (<100 µm) posterior corneal disks. METHODS Twenty five DSAEK grafts were prepared with two sequential cuts: the first cut, of variable thickness, was made with a femtosecond laser and the second with a 300 µm microkeratome head. Spectacle corrected visual acuity, endothelia...

متن کامل

Double-pass microkeratome technique for ultra-thin graft preparation in Descemet’s stripping automated endothelial keratoplasty

Endothelial keratoplasty is evolving with increased attention placed on the optical qualities of the posterior donor lenticule. In efforts to improve visual outcomes, the effects of the thickness, smoothness, and planar profile are being studied. This paper describes a double-pass microkeratome technique to create ultra-thin (less than 100 μm) Descemet's stripping automated endothelial keratopl...

متن کامل

Eventual Endothelial Failure After Initial Corneal Clearing After a Detached Endothelial Graft in Fuchs Dystrophy

mated Bowman layer preparation with a 90to 100-mm-thick donor lamella of anterior stroma (instead of an 8to 12-mm-thick isolated Bowman layer graft). In our experience, the presence of donor stroma seems to degrade the optical quality of the transplanted cornea (as Descemet stripping endothelial keratoplasty/Descemet stripping automated endothelial keratoplasty grafts containing donor stroma ma...

متن کامل

Determinants of visual quality after endothelial keratoplasty.

Endothelial keratoplasty is now favored over full-thickness penetrating keratoplasty for corneal decompensation secondary to endothelial dysfunction. Although endothelial keratoplasty has evolved as surgeons strive to improve outcomes, fewer patients than expected achieve best corrected visual acuity of 20/20 despite healthy grafts and no ocular comorbidities. Reasons for this remain unclear, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2012