Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation

نویسندگان

  • Russell I Heigh
  • John K DiBaise
  • James A Prechel
  • Billie J Horn
  • Sarah San Miguel
  • Evelyn G Heigh
  • Jonathan A Leighton
  • Cynthia J Edgelow
  • David E Fleischer
چکیده

BACKGROUND Safe and effective colonoscopy is aided by the use of endoscopic techniques and maneuvers (ETM) during the examination including patient repositioning, stiffening of the endoscope and abdominal pressure. AIM To better understand the use and value of ETM during colonoscopy by using a device that allows real-time imaging of the colonoscope insertion shaft. METHODS The use of ETM during colonoscopy and their success was recorded. Experienced colonoscopists and endoscopy assistants used a commercially available electromagnetic (EM) transmitter and a special adult variable stiffness instrument with 12 embedded sensors to examine 46 patients. In 5 of these a special EM probe passed through the instrument channel of a standard pediatric variable stiffness colonoscope was used instead of the EM colonoscope. RESULTS Thirty-nine men and 7 women with a mean age of 64 years (range 33-90) were studied. The cecum was intubated in 93.5% (43/46). The mean time to reach the cecum was 10.6 minutes (range 3-25). ETM were used a total of 174 times in 41 of the patients to assist with cecal intubation. When ETM were required to reach the cecum, and the cecum was intubated, an average of 3.82 ETM/patient was used. While ETM were used most often when the tip of the colonoscope was in the left side of the colon (rectum 5.0%, sigmoid colon 20.7%, descending colon 5.0%, and splenic flexure 11.6%), when the instrument was in the transverse colon (14.8%), hepatic flexure (20.7%) and ascending colon (19.8%) the use of ETM was also required. When the colonoscope tip was in the transverse colon, hepatic flexure and ascending colon, ETM success rates were less (61.1%, 52.0%, and 41.7% respectively) compared to the left colon success rates (rectum 83.3%, sigmoid colon 84.0%, descending colon 100%, and splenic flexure 85.7%). CONCLUSION The EM colonoscope allows imaging of the insertion shaft without fluoroscopy and is a useful device for evaluating the efficacy of ETM. ETM are important tools of the colonoscopist and are used most often in the left colon where they are most effective.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does the variable-stiffness colonoscope makes colonoscopy easier? A meta-analysis of the efficacy of the variable stiffness colonoscope compared with the standard adult colonoscope

BACKGROUND The variable-stiffness colonoscope (VSC) appears to have advantages over the standard adult colonoscope (SAC), although data are conflicting. To provide a comprehensive up-to-date review, we conducted a meta-analysis to compare the efficacies of the VSC and SAC. METHODS Electronic databases, including PubMed, EMBASE, the Cochrane library and the Science Citation Index, were searche...

متن کامل

Comparative study of a responsive insertion technology (RIT) colonoscope versus a variable-stiffness colonoscope.

BACKGROUND AND OBJECTIVES recently, Olympus developed a new prototype (XCF-Q180AY2L) with responsive insertion technology (RIT), which besides the still known variable stiffness technology, included a passive bending section and a new high force insertion tube. Our objective was to investigate whether the use of this prototype could ease colonoscope insertion, increasing the cecal intubation ra...

متن کامل

A Randomized Controlled Trial of Comparison on Time and Rate of Cecal and Termianl Ileal Intubation according to Adult-Colonoscope Length: Intermediate versus Long

For a complete colonoscopic examination, a high intubation rate and a short intubation time have been demanded to colonoscopists, if possible. The aim of the present study was to compare these examination parameters, intubation time and rate, according to the length of colonoscope. A total of 507 healthy Korean subjects were randomly assigned into two groups: intermediate length adult-colonosco...

متن کامل

How Do I Overcome Difficulties in Insertion?

Demand for colonoscopy is increasing because it is an important tool not only for screening of colorectal neoplasm but also for resection of such lesions in early stage. Cecal intubation requires expertise on shortening of the examination time and improvement of the cecal intubation rate without causing pain to the patients. About 5% to 10% of patients still experience difficulties or failure o...

متن کامل

Preliminary colonoscopy facilitates retrograde double-balloon enteroscopy

BACKGROUND AND STUDY AIMS Retrograde double-balloon enteroscopy (RDBE) has a high failure rate due to difficulty intubating the ileo-cecal (IC) valve. We examined the utility of a pre-RDBE colonoscopy using a pediatric colonoscope to clean the cecum and perform an initial intubation of the IC valve. PATIENTS AND METHODS This study is a retrospective review of RDBE procedures for 45 patients a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009