The optimal use of cardiac imaging in the quantification of carcinoid heart disease.
نویسندگان
چکیده
Carcinoid heart disease is a rare cause of right-sided valvular dysfunction, primarily mediated by serotonin. It is an important complication in patients with carcinoid syndrome and occurs in 20-50% of such patients. Echocardiography is the main technique used for the assessment of carcinoid heart disease, but other imaging modalities are also important, particularly in the quantification of the severity of the disease. We sought to review the role of cardiac imaging in the assessment of carcinoid heart disease.
منابع مشابه
Evaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics
Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria. Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...
متن کاملHeart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy
This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...
متن کاملUptake index of 123I-metaiodobenzylguanidine myocardial scintigraphy for diagnosing Lewy body disease
Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-tomediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ra...
متن کاملThe Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging
Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Endocrine-related cancer
دوره 20 5 شماره
صفحات -
تاریخ انتشار 2013