Effect of thromboplastin and coagulometer interaction on the precision of the International Normalised Ratio.

نویسندگان

  • D W Pi
  • J M Raboud
  • C Filby
  • C J Carter
چکیده

AIMS To examine the magnitude of thromboplastin and coagulometer interactions on the precision of International Normalised Ratio (INR) values when the manufacturers' recommended instrument specific International Sensitivity Index (ISI) values are adopted for the INR calculation. METHODS The variability of INR values obtained from four automated phototopical coagulometers frequently used in North American laboratories was studied. When used with five commercial thromboplastins of moderate to high sensitivity (ISI values 0.92-1.97), 20 prothrombin time results were generated for each of a population of 98 patients on established warfarin treatment. RESULTS The mean INR values of the patients ranged from 2.05 to 2.81, depending on which reagent/coagulometer combination was used. Within patient variation increased as the median INR value increased. The mean coefficient of variation of within patient INR values was 10%; the mean coefficient of variation of the prothrombin time results in seconds and prothrombin time ratio were 21 and 18%, respectively. CONCLUSIONS There was considerable bias in the estimated ISI values of the thromboplastins compared with the manufacturers' instrument specific ISI value. Despite this apparent imperfection, our study clearly showed that the INR is preferable to other prothrombin time reporting formats for assessing the degree of anticoagulation for patients on warfarin treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of automation on prothrombin time test in NEQAS surveys.

The performance of coagulometers in the National Quality Assessment Scheme (NEQAS) surveys of the prothrombin time conducted between 1986 and 1987 was reviewed. There were sufficient data for analysis for eight types of coagulometer used with a single type of thromboplastin reagent and one instrument with an alternative reagent. The overall reliability efficacy of each instrument was evaluated ...

متن کامل

Effect of international sensitivity index (ISI) of thromboplastins on precision of international normalised ratios (INR)

The contribution of the thromboplastin international sensitivity index (ISI) to the interlaboratory coefficient of variation (CV) of the international normalised ratio (INR) with individual reagents was assessed. In theory the precision of the INR should increase with lower ISI values. An empirical relation has been established between the ISI, the INR, and its CV for two rabbit thromboplastins...

متن کامل

Effect of magnesium contamination in evacuated blood collection tubes on the prothrombin time test and ISI calibration using recombinant human thromboplastin and different types of coagulometer.

UNLABELLED The purpose of the present study was to assess the effect of two types of evacuated blood collection tube on the prothrombin time and international sensitivity index (ISI) of Recombiplastin, a recombinant human thromboplastin. Vacutainer tubes were compared with Venoject II tubes. Magnesium contamination was detected in the sodium citrate solutions contained in the Vacutainer tubes w...

متن کامل

Screening INR deviation of local prothrombin time systems.

AIM To assess the reliability of local international normalised ratios (INR) using a set of three international reference preparation (IRP) certified freeze dried plasmas. METHODS 55 centres in the United Kingdom and the Republic of Ireland participated; 36 centres employed coagulometers and 19 a manual prothrombin time technique, all with the same batch of routine commercial thromboplastin. ...

متن کامل

Assessment of value of calibrated lyophilised plasmas to determine International Sensitivity Index for coagulometers.

An attempt was made to correct for the effects of coagulometers on the International Sensitivity Index (ISI) in a series of collaborative studies. Modified ISI were derived from the prothrombin time results with coagulometer systems using a range of calibrated plasmas. Two alternative approaches to correction of the ISI were evaluated. The first relied on the consensus orthogonal regression slo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 1995