Change on the horizontal and vertical meridians of the cornea after cataract surgery.

نویسندگان

  • J C Merriam
  • L Zheng
  • J Urbanowicz
  • M Zaider
چکیده

PURPOSE To compare the course and magnitude of change on the horizontal and vertical meridians of the cornea after 5 different incisions for cataract: extracapsular cataract extraction (ECCE), 6 mm superior scleral tunnel (6Sup), 3 mm superior scleral tunnel (3Sup), 3 mm temporal scleral tunnel (3Temp), and 3 mm temporal corneal incision (3Cor). METHODS Retrospective chart review of 665 cases of preoperative regular astigmatism. The preoperative keratometry (K) reading was subtracted from the postoperative K reading to determine mean net change on each meridian at 1 day, 1 week, 2 weeks, 1 month, 1.5 months, 2 months, 4 months, 6 months and 12 months and at 6 month intervals thereafter. After the superior incisions, the temporal changes on each meridian are well described by an analytic model with an initial and final plateau. The changes after the temporal incisions are described by a linear equation. RESULTS After each superior incision, the steepness and length of the transition from the initial to final plateau for each meridian depend on incision length. Considering the uncertainty of measuring K, the corneal meridians stabilized 4.5 months after ECCE, 1.2 months after 6Sup, and 0.3 months after 3Sup. No significant change was detected on the horizontal and vertical meridians after 3Temp and 3Cor. CONCLUSION The magnitude and the duration of changes on the horizontal and vertical meridians of the cornea after cataract surgery depend on both incision length and location. Small temporal incisions induce less change than superior incisions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Model of Cornea Deformation

Cornea surgeons have observed that changes in cornea curvature can follow cataract surgery and cause astigmatism. The placement of surgical incisions has been shown to influence these curvature changes. Though empirical data has been collected about this phenomenon, a biomechanical model has not been employed in predicting post-surgical outcomes. This work implemented an incised finite element ...

متن کامل

Vertical and horizontal thickness profiles of the corneal epithelium and Bowman's layer after orthokeratology.

PURPOSE To investigate thickness profile changes of the corneal epithelium and Bowman's layer at the vertical and horizontal meridians with overnight myopia orthokeratology (OK) lenses. METHODS Twenty subjects (age range: 19-33 years) wore reverse-geometry rigid gas-permeable OK lenses in both eyes for 30 days. Before lens wear and after 1, 7, and 30 days of overnight lens wear, evaluation of...

متن کامل

Effect of lamellar flap location on corneal topography after laser in situ keratomileusis.

PURPOSE To investigate the effect of hinge position on corneal topography after laser in situ keratomileusis (LASIK) for myopia. SETTING Academic center and refractive surgery practice. METHODS Topography data obtained from 89 eyes of 46 patients after LASIK were analyzed. Using a system of Cartesian coordinates, data along the horizontal and vertical axes were analyzed, measuring sagittal ...

متن کامل

Digital pupillometry and centroid shift changes after cataract surgery.

PURPOSE To compare postoperative changes in apparent photopic and mesopic pupil size and centration in relation to cornea reflection landmarks after cataract surgery. SETTING LaserVision.gr Clinical and Research Eye Institute, Athens, Greece. DESIGN Prospective consecutive case study. METHODS Pupils were imaged for pupil size and corneal vertex location before and 1-month after cataract s...

متن کامل

تخمین غیرتهاجمی مدول الاستیک چشم کاتاراکته شده خرگوش

    Although cataract is very common and its detection seems apparently easy especially in the mature cataract, its quantitative description to determine the critical value of diagnosis is too difficult. Non-invasive evaluation of the mechanical properties of eye is hampered by the absence of in-vivo methods for direct assessment of the axial length of eye, lens and cornea. In the present study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transactions of the American Ophthalmological Society

دوره 99  شماره 

صفحات  -

تاریخ انتشار 2001