Application of a catalytic combustion sensor (Pellistor) for the monitoring of the explosiveness of a hydrogen-air mixture in the upper explosive limit range
نویسندگان
چکیده
A new technique is presented for continuous measurements of hydrogen contamination by air in the upper explosive limit range. It is based on the application of a catalytic combustion sensor placed in a cell through which the tested sample passes. The air content is the function of the quantity of formed heat during catalytic combustion of hydrogen inside the sensor. There is the possibility of using the method in industrial installations by using hydrogen for cooling electric current generators.
منابع مشابه
Reformer Gas Application in Combustion Onset Control of HCCI Engine
Homogenous charge compression ignition (HCCI) combustion is spontaneous multi-site combustion of a nominally premixed air/fuel mixture that exhibits high rate of pressure rise and short combustion duration. To avoid excessive pressure rise rate and knocking, HCCI engines are fueled with highly diluted mixture using a combination of excess air and/or EGR. HCCI combustion is attractive due to ...
متن کاملA New Analyzer Based on Pellistor Sensor with Neural Network Data Postprocessing for Measurement of Hydrocarbons in Lower Explosive Limit Range
We present the results of a first stage of development work on a new type of analyzer for hydrogen and C(1)-C(3) hydrocarbons concentration measurements in the lower explosive limit range, based on single pellistor sensor with artificial neural network data postprocessing.
متن کاملEffect of Hydrogen Addition to Natural Gas on Homogeneous Charge Compression Ignition Combustion Engines Performance and Emissions Using a Thermodynamic Simulation
The HCCI combustion process is initiated due to auto-ignition of fuel/air mixture which is dominated by chemical kinetics and therefore fuel composition has a significant effect on engine operation and a detailed reaction mechanism is essential to analysis HCCI combustion. A single zone-model permits to have a detailed chemical kinetics modeling for practical fuels. In this study a single-zone ...
متن کاملCFD Study on Hydrogen-Air Premixed Combustion in a Micro Scale Chamber
This paper reports a CFD modeling study to investigate the hydrogen-air mixture combustion in a micro scale chamber. Nine species with nineteen reversible reactions were considered in the premixed combustion model. The effect of operational and geometrical conditions including; combustor size, wall conductivity, reactant flow rates and hydrogen feed splitting on combustion stabilit...
متن کاملThe effects of added hydrogen to the premixed of methane and air in a MEMS channel
In this paper, the effect of adding hydrogen to the composition of methane and air in a micro combustor is investigated by a three-dimensional numerical method. First, the results of the current study in determining the wall temperature of the micro combustion chamber are compared with those obtained from the experimental and numerical results of the previous research. By confirming the numeric...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Automated Methods and Management in Chemistry
دوره 25 شماره
صفحات -
تاریخ انتشار 2003