Screw-shaped endosseous implants that have a turned surface of commercially pure titanium have a disadvantage of requiring a long time for osseointegration while those implants have shown long-term clinical success in single and multiple restorations. Titanium implant surfaces have been modified in various ways to improve biocompatibility and accelerate osseointegration, which results in a shorter edentulous period for a patient. This article reviewed some important modified titanium surfaces, exploring the in vitro, in vivo and clinical results that numerous comparison studies reported. Several methods are widely used to modify the topography or chemistry of titanium surface, including blasting, acid etching, anodic oxidation, fluoride treatment, and calcium phosphate coating. Such modified surfaces demonstrate faster and stronger osseointegration than the turned commercially pure titanium surface. However, there have been many studies finding no significant differences in in vivo bone responses among the modified surfaces. Considering those in vivo results, physical properties like roughening by sandblasting and acid etching may be major contributors to favorable bone response in biological environments over chemical properties obtained from various modifications including fluoride treatment and calcium phosphate application. Recently, hydrophilic properties added to the roughened surfaces or some osteogenic peptides coated on the surfaces have shown higher biocompatibility and have induced faster osseointegration, compared to the existing modified surfaces. However, the long-term clinical studies about those innovative surfaces are still lacking.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

Maintenance of Dental Implants: A Review

  Objective: Successful bonding of a dental implant to bone, which was referred to as osseointegration by Branemark has been well documented. However, long-term prognosis of an implant depends on adequate maintenance and long-term care. An effective maintenance program is required to preserve the health of peri-implant tissues. Several techniques have been suggested for this purpose but it is n...

متن کامل

Biologic Width around Dental Implants: An Updated Review

Soft tissue-implant interface is an important anatomical feature contributing to the long-term success of dental implants. Based on the available evidence, different factors may influence biological width around implants including the surgical technique, implant loading, implant surface properties, abutment materials, implant position, and width of the peri-implant mucosa. The purpose of the pr...

متن کامل

Implant surface modification: review of literature

The attachment of cells to titanium surfaces is an important phenomenon in the area of clinical implant dentistry. A major consideration in designing implants has been to produce surfaces that promote desirable responses in the cells and tissues. To achieve these requirements, the titanium implant surface can be modified in various ways. This review mainly focuses on the surface topography of d...

متن کامل

A short review on Ferrofluids surface modification by natural and biocompatible polymers

This paper provides an overview of how the surface properties of ferromagnetic nanoparticles dispersed in fluids is modified by natural and biocompatible polymers. Among common magnetic nanoparticles, magnetite (Fe3O4) and maghemite (g-Fe203) are popular candidates because of their biocompatibility. Natural polymeric coating materials are the most commonly used biocompatible magnetic nanopartic...

متن کامل

Guided bone regeneration: A literature review

Guided bone regeneration (GBR) is a reconstructive procedure of alveolar ridge using membranes. This procedure is indicated when there is no sufficient bone for implantation, or in the case of optimal implant installation for esthetic or functional needs. GBR can be performed before implant placement, when there is not enough bone for initial stability of implants and less predictable outcomes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014