Relapse patterns after radiochemotherapy of glioblastoma with FET PET-guided boost irradiation and simulation to optimize radiation target volume
نویسندگان
چکیده
BACKGROUND O-(2-18 F-fluoroethyl)-L-tyrosine-(FET)-PET may be helpful to improve the definition of radiation target volumes in glioblastomas compared with MRI. We analyzed the relapse patterns in FET-PET after a FET- and MRI-based integrated-boost intensity-modulated radiotherapy (IMRT) of glioblastomas to perform an optimized target volume definition. METHODS A relapse pattern analysis was performed in 13 glioblastoma patients treated with radiochemotherapy within a prospective phase-II-study between 2008 and 2009. Radiotherapy was performed as an integrated-boost intensity-modulated radiotherapy (IB-IMRT). The prescribed dose was 72 Gy for the boost target volume, based on baseline FET-PET (FET-1) and 60 Gy for the MRI-based (MRI-1) standard target volume. The single doses were 2.4 and 2.0 Gy, respectively. Location and volume of recurrent tumors in FET-2 and MRI-2 were analyzed related to initial tumor, detected in baseline FET-1. Variable target volumes were created theoretically based on FET-1 to optimally cover recurrent tumor. RESULTS The tumor volume overlap in FET and MRI was poor both at baseline (median 12 %; range 0-32) and at time of recurrence (13 %; 0-100). Recurrent tumor volume in FET-2 was localized to 39 % (12-91) in the initial tumor volume (FET-1). Over the time a shrinking (mean 12 (5-26) ml) and shifting (mean 6 (1-10 mm) of the resection cavity was seen. A simulated target volume based on active tumor in FET-1 with an additional safety margin of 7 mm around the FET-1 volume covered recurrent FET tumor volume (FET-2) significantly better than a corresponding target volume based on contrast enhancement in MRI-1 with a same safety margin of 7 mm (100 % (54-100) versus 85 % (0-100); p < 0.01). A simulated planning target volume (PTV), based on FET-1 and additional 7 mm margin plus 5 mm margin for setup-uncertainties was significantly smaller than the conventional, MR-based PTV applied in this study (median 160 (112-297) ml versus 231 (117-386) ml, p < 0.001). CONCLUSIONS In this small study recurrent tumor volume in FET-PET (FET-2) overlapped only to one third with the boost target volume, based on FET-1. The shrinking and shifting of the resection cavity may have an influence considering the limited overlap of initial and relapse tumor volume. A simulated target volume, based on FET-1 with 7 mm margin covered 100 % of relapse volume in median and led to a significantly reduced PTV, compared to MRI-based PTVs. This approach may achieve similar therapeutic efficacy but lower side effects offering a broader window to intensify concomitant systemic treatment focusing distant failures.
منابع مشابه
Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison
BACKGROUND Biological brain tumor imaging using O-(2-[18F]fluoroethyl)-L-tyrosine (FET)-PET combined with inverse treatment planning for locally restricted dose escalation in patients with glioblastoma multiforme seems to be a promising approach.The aim of this study was to compare inverse with forward treatment planning for an integrated boost dose application in patients suffering from a glio...
متن کاملBiological tumor volume in 18FET-PET before radiochemotherapy correlates with survival in GBM.
OBJECTIVE The aim of this prospective longitudinal study was to identify static and dynamic O-(2-[(18)F]fluoroethyl)-L-tyrosine PET ((18)FET-PET)-derived imaging biomarkers in patients with glioblastoma (GBM). METHODS Seventy-nine patients with newly diagnosed GBM were included; 42 patients underwent stereotactic biopsy (unresectable tumors) and 37 patients microsurgical tumor resection. All ...
متن کاملHypofractionated High-Dose Irradiation with Positron Emission Tomography Data for the Treatment of Glioblastoma Multiforme
This research paper presents clinical outcomes of hypofractionated high-dose irradiation by intensity-modulated radiation therapy (Hypo-IMRT) with (11)C-methionine positron emission tomography (MET-PET) data for the treatment of glioblastoma multiforme (GBM). A total of 45 patients with GBM were treated with Hypo-IMRT after surgery. Gross tumor volume (GTV) was defined as the area of enhanced l...
متن کاملUltrasound-guided boost irradiation of tumor cavity after lumpectomy in breast cancer
Background: After breast conserving surgery, most recurrences occur around the primary tumor site. This justifies the use of boost radiotherapy to the primary site of tumor. Surgical scar is not always a good surrogate for the location of the lumpectomy cavity. The aim of this study was to evaluate ultrasonic guidance for detection of the lumpectomy cavity after breast conserving surgery ...
متن کاملThe impact of 18 F-FET PET-CT on target definition in image-guided stereotactic radiotherapy in patients with skull base lesions
BACKGROUND 18 F-fluoro-ethyl-tyrosine PET is gaining more indications in the field of oncology. We investigated the potentials of usage of FET-PET/CT in addition to MRI for definition of gross tumor volume (GTV) in stereotactic radiotherapy of lesions of skull base. METHODS We included in a prospective setting 21 cases. An MRI was performed, completed by FET PET/CT. Different GTV's were defin...
متن کامل