A power-law model of blood flow through a tapered overlapping stenosed artery
نویسندگان
چکیده
A mathematical model of non-Newtonian blood flow through a tapered stenotic artery is considered. The non-Newtonian model chosen is characterized by the generalized power-law model incorporating the effect of tapering due to the pulsatile nature of blood flow. The flow is assumed to be unsteady, laminar, two-dimensional and axisymmetric. The governing equations of motion in terms of the viscous shear stress in the cylindrical coordinate system are solved numerically using a finite difference scheme. Numerical results obtained for the positive taper angle show that the blood flow characteristics such as the axial velocity profiles, flow rate and wall shear stress have lower values, while the resistive impedances have higher values than the Newtonian model. 2007 Published by Elsevier Inc.
منابع مشابه
Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...
متن کاملNumerical Modeling of Two-Layered Micropolar Fluid Through an Normal and Stenosed Artery
In the present work a two fluid model for blood flow through abnormally constrictedhuman artery (stenosed artery) has been developed. The model consists of a core region of suspensionof all erythrocytes assumed to be micro-polar fluid so as to include the micro-structural effects inaddition to the peripheral-layer viscosity effects, and a peripheral plasma layer free from cells of anykind of Ne...
متن کاملMHD Flow of Blood through Radially Non-symmetric Stenosed Artery: a Hershcel-Bulkley Model (RESEARCH NOTE)
The purpose of this study is to develop a mathematical model for studying the magnetic field effect on blood flow through an axially non-symmetric but radially symmetric atherosclerotic artery. Herschel-Bulkley equation has been taken to represent the non-Newtonian character of blood. The response of magnetic field, stenosis height, shape parameter on velocity, volumetric flow rate in stenotic ...
متن کاملMathematical modelling of Sisko fluid flow through a stenosed artery
In the present study, the nonlinear model of non-Newtonian blood flow in cosine-shape stenosed elastic artery is numerically examined. The model is carried out for axisymmetric, two-dimensional and fully developed blood flow. The vessel wall is assumed to be have time-dependent radius that is important factor for study of blood flow. The cosine-shape stenosis convert to rigid artery by using a ...
متن کاملMathematical modeling of blood flow in a stenosed artery under MHD effect through porous medium
In this investigation, a mathematical model for studying oscillatory flow of blood in a stenosed artery under the influence of transverse magnetic field through porous medium has been developed. The equations of motion of blood flow are solved analytically. The analytical expressions for axial velocity, volumetric flow rate, pressure gradient, resistance to blood flow and shear stress have been...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied Mathematics and Computation
دوره 195 شماره
صفحات -
تاریخ انتشار 2008