Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm® Guided Methods
نویسندگان
چکیده
OBJECTIVE The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm® system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. METHODS Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws from T5 to S1 in 45 patients. The position of screws within the pedicle was classified into four groups, from grade 0 (no violation cortex) to 3 (more than 4 mm violation). The location of violated pedicle cortex was also assessed. Intra-operative parameters including time required for preparation of screwing procedure, times for screwing and the number of X-ray shot were assessed in each group. RESULTS Grade 0 was observed in 186 (91.2%) screws of the fluoroscopy-guided group, and 99 (93.4%) of the navigation-guided group. Mean time required for inserting a screw was 3.8 minutes in the fluoroscopy-guided group, and 4.5 minutes in the navigation-guided group. Mean time required for preparation of screw placement was 4 minutes in the fluoroscopy-guided group, and 19 minutes in the navigation-guided group. The fluoroscopy-guided group required mean 8.9 times of X-ray shot for each screw placement. CONCLUSION The screw placement under the navigation-guidance coupled with O-arm® system appears to be more accurate and safer than that under the fluoroscopy guidance, although the preparation and screwing time for the navigation-guided surgery is longer than that for the fluoroscopy-guided surgery.
منابع مشابه
Accuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملAccuracy of Pedicle Screw Placement in Scoliosis Surgery: A Comparison between Conventional Computed Tomography-Based and O-Arm-Based Navigation Techniques
STUDY DESIGN Retrospective study. PURPOSE We compared the accuracy of O-arm-based navigation with computed tomography (CT)-based navigation in scoliotic surgery. OVERVIEW OF LITERATURE No previous reports comparing the results of O-arm-based navigation with conventional CT-based navigation in scoliotic surgery have been published. METHODS A total of 222 pedicle screws were implanted in 29...
متن کاملCommentary: Utility of the O-Arm in spinal surgery
BACKGROUND More studies report the intraoperative benefits vs. risks of utilizing the O-Arm in performing pedicle screw insertion in spinal surgery. METHODS/RESULTS Several studies document the utility of CT-guided O-arm placement of pedicle/lateral mass screws. Singh et al. documented the efficacy of CT guided-O Arm placement of pedicle screws and lateral mass screws in the upper cervical sp...
متن کاملNavigation on the Thoracic and Lumbar Spine
tem since their introduction in clinical application in 1995 [1, 26]. The navigation at the spine with the help of a CT-based navigation, or the navigation using a 2D data set, from a conventional image converter, have become established methods at centers working with navigation. Numerous publications proof that these systems can be utilized in clinical practice, and in most cases contribute t...
متن کاملUse of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
BACKGROUND A quantitative screw accuracy system is proposed that allows for high-fidelity discrimination between various methods of pedicle screw insertion. Our purpose was to study the utility of a quantitative screw accuracy scoring system to assess new imaging technologies and their effects on the minimally invasive spine learning curve. METHODS By use of a hypothetical "perfect screw," a ...
متن کامل