Radiation Effects on Digital Radiography

نویسندگان

  • Ho Kyung Kim
  • Min Kook Cho
چکیده

In the moment of any given imaging task and thus over the lifetime of a detector, the deposition of certain amount of radiation dose in an electronic pixel element is inevitable. This radiation effect can give rise to a change of the pixel-element characteristics such as the leakage current of a photodiode and the threshold voltage of thin-film transistors (TFTs) [1], and which may consequently result in the degradation of image quality of imaging detectors. While a large amount of effort has been invested in the evaluation of performance degradation of the pixel element devices themselves due to the radiation damage, there has been no sufficient attention paid to the evaluation of imagequality degradation although that is an important issue regarding the quality control and assurance of detectors and thus their lifetime. In this study, we have studied radiation effects on the image quality of a photodiode array detector made by complementary metal-oxide-semiconductor (CMOS) process in conjunction with a phosphor screen. We report the observation of an image-quality degradation by assessing MTF (modulation-transfer function), NPS (noise-power spectrum) and DQE (detective quantum efficiency) with respect to the total ionizing dose at the detector entrance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

Dose Evaluation for Common Digital Radiographic Examinations in Selected Hospitals in Pahang Malaysia

Introduction: In digital radiography, radiographers tend to increase exposure factors to acquire an acceptable image quality thereby increasing radiation dose to patients.  Regarding this, the present study aimed to re-evaluate the exposure parameters and to ascertain the entrance surface dose (ESD) and effective dose (ED) of posterior-anterior (PA) chest, abdomen, and anterior-posterior (AP) l...

متن کامل

Effects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography

Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...

متن کامل

Beliefs and behaviors of radiographers concerning “Digital Chest Radiography”

Aims Chest radiography is the first choice for the investigation of cardiovascular and respiratory disease. Radiographer technologists are responsible for managing the radiation exposure to patients and providing adequate image quality according to the ALARA concept. The knowledge and experience of radiographers in performing chest radiography helps to improve the diagnosis of diseases. The aim...

متن کامل

Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007