Assessment of the reliability of real time ultrasound scanning to measure the humeral head position in a number of glenohumeral joint positions
نویسندگان
چکیده
The aim of the current study is to assess the intra-rater and inter-rater reliability of real time ultrasound scanning in measuring static humeral head position. Real time ultrasound scanning, an experimental clinical measurement, was used to record measurements of the humeral head position in a sample of (20) healthy volunteers [9 male, 11 female]. While the participant was seated in a standardized chair, Hips and knees were positioned at 90 degrees of flexion. The humeral head position of each subject was imaged at three ultrasound view [anterior, posterior and superior] in a different arm positions; images were repeated three times for each position by the same examiner on the same day to assess Intra-rater reliability. The Images were then analysed by the researcher and a second investigator to assess inter-tester reliability. Intra-rater and inter-rater reliability were quantified by using the intraclass correlation coefficient and standard error of measurement, the smallest detectable difference values were calculated and were used to estimate the magnitude of change that is predictable to exceed measurement error. The intra-rater reliability for all positions was found to be excellent for all tests ranged from 0.83 to 0.99 respectively. Inter –rater reliability between examiners was found to be good to excellent for all test positions ranged from 0.66 to 0.98, and the standard error of measurement for all positions was less than the calculated mean. This study demonstrates that real time ultrasound scanning is a reliable method of assessing the location of the humeral head in a number of arm positions in healthy subjects when measured by the same examiner and this may suggest that RTUS could be used to assess the impact of rehabilitation programme or surgical interventions for shoulder pathology.
منابع مشابه
Osteochondritis Dissecans of the Humeral Head: A Case Report and Review of the Literature
Osteochondritis dissecans (OCD) is a common joint disorder in knee, ankle and elbow, however it can be rarely found in glenohumeral joint. In this study, we report an asymptomatic case of humeral head OCD, which was detected incidentally following a trauma. X-rays showed an area of lucency around an oval bony fragment measuring about 1 cm on the superior aspect of the humeral head. However, ...
متن کاملTranslational movement within the glenohumeral joint at different rotation velocities as seen by cine MRI
BACKGROUND The glenohumeral joint is subjected to opposing forces when the direction of shoulder motion is changed, accelerating and decelerating to make the movements. The influence of motion velocity or acceleration on translation of the humeral head has not been evaluated although direction and distance of humeral head translation has been analyzed in real time in normal shoulders. We hypoth...
متن کاملRotator cuff fatigue and glenohumeral kinematics in participants without shoulder dysfunction.
CONTEXT Researchers have established that superior migration of the humeral head increases after fatigue of the rotator cuff muscles. In these studies, the investigators used imaging techniques to assess migration of the humeral head during statically held shoulder positions. Their results may not represent the amount of superior humeral head migration that occurs during dynamic arm elevation. ...
متن کاملTHE EVALUATION OF SYMMETRIC RESTING SCAPULAR POSTURE AND SCAPULOHUMERAL RHYTHM RATIO BETWEEN DOMINANT AND NON-DOMINANT SHOULDERS IN ELDERLY SUBJECTS IN DIFFERENT HUMERAL ABDUCTION ANGLES
Background & Aims: Previous studies have stated that the scapulohumeral rhythm dysfunction can make a person prone to glenohumeral joint pathologies. The purpose of this study was to survey symmetric resting scapular posture and scapulohumeral rhythm ratio between dominant and non-dominant shoulders in elderly subjects in different humeral abduction angles. Materials & Methods: Thirty-five hea...
متن کاملBiomechanical comparison of anatomic humeral head resurfacing and hemiarthroplasty in functional glenohumeral positions.
BACKGROUND Resurfacing of the humeral head has gained interest as an alternative to traditional hemiarthroplasty because it preserves bone stock and respects the native geometry of the glenohumeral articulation. The purpose of this study was to compare the biomechanics of the intact glenohumeral joint with those following humeral head resurfacing and following hemiarthroplasty. METHODS Seven ...
متن کامل