UNLABELLED Fixed orthodontic appliances make it difficult to maintain the oral hygiene, resulting in plaque accumulation. Retention of bacterial plaque, represents a risk for white spot lesions and development of periodontal disease. AIM Purpose of this study was to determine in vivo the retention of plaque on three different elastic ligatures, in comparison with stainless steel ligature, to determine a possible association between type of ligatures and accumulation of microorganisms. MATERIAL AND METHODS THREE ELASTIC LIGATION SYSTEMS WERE ANALYZED FOR PLAQUE RETENTION: ring-shape, clear, latex ligatures (Leone® Spa), ring-shape, grey, polyurethane ligatures (Micerium® Spa) and grey, polyurethane, Slide low-friction ligatures (Leone® Spa), compared with stainless steel ligatures (Leone® Spa) used as control. Forthy orthodontic patients undergoing fixed orthodontic therapy were selected. A sample for each type of ligature were applied inside the oral cavity of each subject. Samples were kept in the oral cavity for 28 days, ligating 0.16 X 0.22 stainless steel archwire to stainless steel orthodontic premolars brackets. The presence of bacterical slime was quantified by spectrophotometric method (crystal violet-Bouin's fixative) and morphological observations was evaluated by Scanning Electron Microscopy (SEM). RESULTS From analysis of bacterical slime emerges that all the elastics showed a low plaque retention, especially if compared to the group of steinless steel ligatures, that presented a greater plaque adhesion, statistically significant compared to the Slide group (r<0.0002) and the two elastic groups (r<0.0001). This study reported no significant difference between the Slide ligatures and the traditional elastic ligatures as regards the retention of plaque. SEM images showed presence of cocci, rods and few filamentous organisms and an interbacterial matrix in all observed samples. CONCLUSION Elastomeric ligatures showed a significant lower susceptibility to plaque adhesion, in comparison to the stainless steel of the metallic ligatures. No statistically significant difference was observed among the elastic devices.
منابع مشابه
Evaluation of Micro-organism in Ligated Metal and Self-ligating Brackets using Scanning Electron Microscopy: An In Vivo Study
BACKGROUND The objective of the study was to determine the sites of plaque accumulation and to compare the plaque accumulated with metal and self-ligating orthodontic brackets in order to know which bracket type had a higher plaque retaining capacity. MATERIALS AND METHODS The study was done on 20 subjects who were scheduled for orthodontic treatment including extraction of four premolars and...
متن کاملAntimicrobial Effect of Zataria Multiflora Extract in Comparison with Chlorhexidine Mouthwash on Experimentally Contaminated Orthodontic Elastomeric Ligatures
OBJECTIVES Long-term use of orthodontic appliances and fixation ligatures creates a favorable environment for the accumulation of oral normal microflora and increases the risk of enamel demineralization and periodontal disease. The aim of this study was to compare the antimicrobial effects of Zataria Multiflora extract and 0.2% chlorhexidine (CHX) mouthwash on experimentally contaminated orthod...
متن کاملEvaluation of the Effect of Different Ligature System On Microbial Attack
The objective of this study was to investigate the effect of elastomeric and stainless steel ligatures on the microbiology of local dental plaque. Clinical reports have shown that patients who receive orthodontic treatment are more susceptible to enamel white spot formation. Metallic orthodontic brackets have also been found to inflict ecologic changes in the oral environment, such as decreased...
متن کاملEffect on Mechanical Properties of Orthodontic Elastomeric Ligatures on Immersion in Disinfecting Solutions - an in vitro Study
Background and Objectives: Cold water disinfection can damage the elastomeric material, cross contamination in handling elastomeric ligatures is a serious concern in the orthodontic office. In addition, elastomeric strips with enough ligatures for both arches of a single patient are produced by most manufacturers. Thus, cross -contamination can occur in remaining ligatures if an entire strip is...
متن کاملAnalysis of the Influence of Food Colorings in Esthetic Orthodontic Elastomeric Ligatures
PROPOSITION The purpose of this study was to evaluate in vitro the color changes of esthetic orthodontic elastomeric ligatures of different shades when exposed to four food colorings commonly found in the diet of patients. MATERIALS AND METHODS The sample consisted of esthetic orthodontic elastomeric ligatures in the colors pearl, pearl blue, pearl white and colorless, which were immersed for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- ORAL & implantology
دوره 5 4 شماره
صفحات -
تاریخ انتشار 2012