Rician Noise Removal in Diffusion Tensor MRI
نویسندگان
چکیده
Rician noise introduces a bias into MRI measurements that can have a significant impact on the shapes and orientations of tensors in diffusion tensor magnetic resonance images. This is less of a problem in structural MRI, because this bias is signal dependent and it does not seriously impair tissue identification or clinical diagnoses. However, diffusion imaging is used extensively for quantitative evaluations, and the tensors used in those evaluations are biased in ways that depend on orientation and signal levels. This paper presents a strategy for filtering diffusion tensor magnetic resonance images that addresses these issues. The method is a maximum a posteriori estimation technique that operates directly on the diffusion weighted images and accounts for the biases introduced by Rician noise. We account for Rician noise through a data likelihood term that is combined with a spatial smoothing prior. The method compares favorably with several other approaches from the literature, including methods that filter diffusion weighted imagery and those that operate directly on the diffusion tensors.
منابع مشابه
A Novel Approach for Statistical Estimation of HARDI Diffusion Parameters from Rician and Non-Central Chi Magnitude Images
Introduction: The statistics of noisy MRI magnitude and root sum-of-squares (SoS) images are accurately modeled by the Rician and non-central chi (NCC) probability distributions, respectively [1]. In diffusion MRI (dMRI), the noise bias introduced by these distributions leads to distortion of estimated quantitative diffusion parameters [2]. One approach to addressing this noise bias is to denoi...
متن کاملروشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملRobust Diffusion Tensor Estimation by Maximizing Rician Likelihood
Introduction: Diffusion tensor imaging (DTI) is widely used to characterize white matter in health and disease. Previous approaches to the estimation of diffusion tensors have either been statistically suboptimal or have used Gaussian approximations of the underlying noise structure, which is Rician in reality. The most prevalent tensor estimation method, the log-linear minimum mean squared err...
متن کاملNEX or no NEX? A high angular resolution diffusion imaging study
INTRODUCTION: To remove noise artifacts and enhance SNR, diffusion-weighted (DW) measurements are often repeated multiple times (NEX) along each gradient direction (typically, from 2 to 4 measurements) and each DW image is averaged. This averaging increases acquisition time considerably. It is also not clear what effects it has on the reconstructed diffusion profiles such as the orientation dis...
متن کاملRician Noise Removal by Non-Local Means Filtering for Low Signal-to-Noise Ratio MRI: Applications to DT-MRI
Diffusion-Weighted MRI (DW-MRI) is subject to random noise yielding measures that are different from their real values, and thus biasing the subsequently estimated tensors. The Non-Local Means (NLMeans) filter has recently been proposed to denoise MRI with high signal-to-noise ratio (SNR). This filter has been shown to allow the best restoration of image intensities for the estimation of diffus...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 9 Pt 1 شماره
صفحات -
تاریخ انتشار 2006