Background and purpose - Hexapod ring fixators such as the Taylor Spatial Frame (TSF) have shown good outcomes. However, there have only been a few studies comparing the use of TSF with various etiologies of the deformity. We compared the use of TSF in congenital and acquired deformities in children. Patients and methods - We reviewed 213 lower extremity reconstructive procedures with the TSF in 192 patients who were operated between October 2000 and October 2015. 128 procedures (67 proximal tibiae, 51 distal femora, and 10 distal tibiae) in 117 children (median age 14 (4-18) years; 59 girls) fulfilled the inclusion criteria. 89 procedures were done in children with congenital deformities (group C) and 39 were done in children with acquired deformities (group A). Outcome parameters were lengthening and alignment achieved, lengthening index, complications, and analysis of residual deformity in a subgroup of patients. Results - Mean lengthening achieved was 3.9 (1.0-7.0) cm in group C and 3.7 (1.0-8.0) cm in group A (p = 0.5). Deformity parameters were corrected to satisfaction in all but 3 patients, who needed further surgery for complete deformity correction. However, minor residual deformity was common in one-third of the patients. The mean lengthening index was 2.2 (0.8-10) months/cm in group C and 2.0 (0.8-6) months/cm in group A (p = 0.7). Isolated analysis of all tibial and femoral lengthenings showed similar lengthening indices between groups. Complication rates and the need for secondary surgery were much greater in the group with congenital deformities. Interpretation - The TSF is an excellent tool for the correction of complex deformities in children. There were similar lengthening indices in the 2 groups. However, congenital deformities showed a high rate of complications, and should therefore be addressed with care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Callus massage after distraction osteogenesis using the concept of lengthening then dynamic plating

Correction of complex deformities is a challenging procedure. Long-term wearing of a fixator after correction and lengthening are inconvenient and has a high rate of complication. The goals of the surgical treatment in the presented case were: (1) correction of the deformity and lengthening of the left leg by the Taylor spatial frame (TSF, Smith and Nephew, Marl, Germany); (2) reduction in the ...

متن کامل

Limb lengthening and correction of deformity in the lower limbs of children with osteogenesis imperfecta.

We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov fr...

متن کامل

The role of Taylor Spatial Frame for the treatment of acquired and congenital tibial deformities in children.

This study evaluates the use of the Taylor Spatial Frame (TSF) for the correction of acquired and congenital tibial deformities in children. The purpose is to underline problems, obstacles and complications that can be observed during treatment to reveal the learning curve and potential risk factors and to propose solutions to avoid difficulties during its use 86 tibia deformities were correcte...

متن کامل

Pediatric and adolescent applications of the Taylor Spatial Frame.

Limb deformity can occur in the pediatric and adolescent populations from multiple etiologies: congenital, traumatic, posttraumatic sequelae, oncologic, and infection. Correcting these deformities is important for many reasons. Ilizarov popularized external fixation to accomplish this task. Taylor expanded on this by designing an external fixator in 1994 with 6 telescoping struts that can be se...

متن کامل

Analysis of radiographic bone parameters throughout the surgical lengthening and deformity correction of extremities.

BACKGROUND Radiographic examination of extremities in surgical lengthening and/or correction of deformities is of crucial importance for the assessment of new bone formation. The purpose of this study is to confirm the diagnostic value of radiography in precise detection of bone parameters in various lengthening or correction stages in patients treated by limb-lengthening and deformity correcti...