Patient Body Weight-Tailored Contrast Medium Injection Protocol for the Craniocervical Vessels: A Prospective Computed Tomography Study

نویسندگان

  • Rebecca Kessler
  • Katrin Hegenscheid
  • Steffen Fleck
  • Alexander Khaw
  • Michael Kirsch
  • Norbert Hosten
  • Sönke Langner
چکیده

OBJECTIVES To evaluate body weight-tailored contrast medium (CM) administration for computed tomography angiography (CTA) of the craniocervical vessels. METHODS Institutional review board approval was obtained, and all patients gave written informed consent. Sixty patients were consecutively assigned to one of three dose groups (20 patients per group) with CM doses of Visipaque 270® (iodixanol 270 mg/ml) tailored to body weight at doses of 1.5, 1.0, or 0.5 ml/kg. Region-of-interest (ROI) analysis of maximum enhancement (ME) was conducted, and signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were calculated. Retrospective comparison was performed with three matched control groups examined with a standard CM dose (80 ml of Visipaque 270®). Image quality was rated by two neuroradiologists blinded to the CM dose used. Interrater reliability was calculated using kappa statistics. RESULTS Body weight/BMI and ME were inversely correlated in the three control groups receiving the standard dose (r = -0.544/-0.597/-0.542/r = -0.358/r = -0.424/r = -0.280). Compared to standard dose, 1.5 ml/kg produced higher ME, SNR, and CNR in the anterior circulation (p≤0.038), 1.0 ml/kg had higher ME in cervical and medium-sized cerebral arteries (p≤0.034), and 0.5 ml/kg had lower ME, SNR and CNR for medium-sized cerebral arteries (p≤0.049). ME, SNR, and CNR were the same for 1.5 ml/kg and 1.0 ml/kg (p≥0.24), and both had higher values compared to 0.5 ml/kg (p≤0.043/p≤0.028). In patients with BMI>25, 1.5 ml/kg and 1.0 ml/kg produced higher ME than standard dose (p<0.001/p = 0.008), but ME in patients with BMI>25 did not differ between group 1 and group 2 (p = 0.673). In patients with BMI≤25, 1.5 ml/kg and 1.0 ml/kg produced ME comparable to standard dose (p = 0.132/p = 0.403). Regardless of patient weight, 0.5 ml/kg yielded lower ME than standard dose (p = 0.019/0.002). CONCLUSIONS Craniocervical CTA with a body weight-tailored CM dose of 1.0 ml/kg (270 mg iodine/ml) reduces iodine load in patients weighing <80 kg while producing ME similar to standard dose and improves ME in patients with BMI>25.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography

To determine whether body weight and concentration dependent contrast medium (CM) injection protocols can improve patient to patient CT value uniformity more than the conventional injection protocols with fixed injection parameters in coronary CT angiography (CCTA), one hundred and sixty patients who underwent CCTA were prospectively randomized into two groups. Group A (n = 80) used individuali...

متن کامل

The efficacy of contrast protocol in hepatic dynamic computed tomography: multicenter prospective study in community hospitals

PURPOSE To investigate four different contrast protocols to detect hypervascular hepatocellular carcinoma (HCC) most adaptable for patients at any body weight (BW) in clinical practice. MATERIALS AND METHODS A post-marketing surveillance of liver dynamic CT was prospectively performed by four different protocols in 415 patients: Protocol-A, BW-tailored dose of contrast media (CM: iohexol 300 ...

متن کامل

Assessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran

 Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...

متن کامل

Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria

Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...

متن کامل

Whole-body CT trauma imaging with adapted and optimized CT angiography of the craniocervical vessels: do we need an extra screening examination?

BACKGROUND AND PURPOSE Blunt carotid and vertebral artery injury (BCVI) is rare but potentially devastating. The objective of our study was to prospectively evaluate the usefulness of a dedicated and optimized CT angiography (CTA) protocol of the craniocervical vessels as part of a whole-body CT work-up of patients with multiple trauma in a population of patients with blunt trauma. MATERIAL A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014