Evaluating Loading Deflection of Distraction Osteogenic Rib in a Rabbit Model
نویسندگان
چکیده
BACKGROUND The treatment of patients with partially atrophic rib and rib defects requires an ideal arc of the rib that has adequate bone length and width. To design and assemble a distraction device with a strain gauge, we need to establish an animal model for testing it during rib distraction osteogenesis. METHODS Osteotomies were performed at the same position in the fifth rib in 8 rabbits. Customized distraction devices attached to strain gauges were used to distract the ribs. After a month of distraction and consolidation, loading deflection gauges were used, and specimens were examined histologically to record bone formation. RESULTS Distraction osteogenesis was carried out successfully in all rabbits when the device used to distract the rib up to 4 cm. CONCLUSIONS The device can be used for strain testing during rib distraction osteogenesis performed in a rabbit model. There was no significant difference in the loading deflection gauges of the bone between osteogenic and contralateral ribs. This animal model of costal distraction osteogenesis is successful.
منابع مشابه
Chest deflection tolerance to blunt anterior loading is sensitive to age but not load distribution.
Ninety-three human cadaver tests are used in the development of thoracic injury risk functions with consideration of age and restraint condition. Linear logistic regression models are developed with the set of potential predictors including the maximum chest deflection, the age of the cadaver at death, gender, and the loading condition on the anterior thorax: blunt hub (41 tests), seat belt (26...
متن کاملSong 1 DEVELOPMENT OF INJURY CRITERIA FOR FRONTAL IMPACT USING A HUMAN BODY FE MODEL
Sternal deflection is an injury criterion used in current regulatory and consumer tests worldwide to assess thoracic injury risk. However, this criterion has some serious limits when applied to the Hybrid-III dummy: the risk curve based on the criterion is restraint dependent, and it does not allow discrimination between some advanced restraint systems. The THOR dummy, despite its better biofid...
متن کاملEffects of implantation of bone marrow mesenchymal stem cells, disc distraction and combined therapy on reversing degeneration of the intervertebral disc.
Although success has been achieved with implantation of bone marrow mesenchymal stem cells (bMSCs) in degenerative discs, its full potential may not be achieved if the harsh environment of the degenerative disc remains. Axial distraction has been shown to increase hydration and nutrition. Combining both therapies may have a synergistic effect in reversing degenerative disc disease. In order to ...
متن کاملDetermining the critical size of a rabbit rib segmental bone defect model
In order to establish and standardize the rabbit rib segmental bone defect model, it is of vital importance to determine rabbit rib critical size defect (CSD). According to the general time needed for spontaneous long-bone regeneration, three-month observation period was set to determine the CSD. The rabbit rib segmental bone defects with different sizes from 1 to 5 cm with or without periosteu...
متن کاملPREDICTION OF LOAD DEFLECTION BEHAVIOUR OF TWO WAY RC SLAB USING NEURAL NETWORK APPROACH
Reinforced concrete (RC) slabs exhibit complexities in their structural behavior under load due to the composite nature of the material and the multitude and variety of factors that affect such behavior. Current methods for determining the load-deflection behavior of reinforced concrete slabs are limited in scope and are mostly dependable on the results of experimental tests. In this study, an ...
متن کامل