Concordance and population studies along with stutter and peak height ratio analysis for the PowerPlex ® ESX 17 and ESI 17 Systems.

نویسندگان

  • Carolyn R Hill
  • David L Duewer
  • Margaret C Kline
  • Cynthia J Sprecher
  • Robert S McLaren
  • Dawn R Rabbach
  • Benjamin E Krenke
  • Martin G Ensenberger
  • Patricia M Fulmer
  • Douglas R Storts
  • John M Butler
چکیده

The PowerPlex(®) ESX 17 and ESI 17 Systems for short tandem repeat (STR) amplification were developed by the Promega Corporation to meet the European Network of Forensic Science Institutes (ENFSI) and the European DNA Profiling (EDNAP) Group recommendations for increasing the number of STR loci included in the European Standard Set (ESS). The PowerPlex ESX 17 and ESI 17 Systems utilize different PCR primer combinations to co-amplify the following 17 loci: D1S1656, D2S441, D2S1338, D3S1358, D8S1179, D10S1248, D12S391, D16S539, D18S51, D19S433, D21S11, D22S1045, FGA, TH01, vWA, SE33, and the sex-typing locus amelogenin. A total of 1443 U.S. population samples were evaluated with pre-commercialization versions of both kits. Stutter and heterozygote peak height ratios have been used to characterize kit performance. Typing results have been used to estimate the match probabilities provided by the chosen loci as well as in concordance studies. Full concordance between the typing results for the two kits was observed in 99.994% (49,055 out of 49,062) STR allele calls compared. All genotyping discrepancies were confirmed by DNA sequence analysis. As a result of these comparisons, a second forward primer for the D22S1045 locus has been added to the PowerPlex ESX 17 System to address a primer binding site mutation and the D1S1656 locus reverse primer in the PowerPlex ESI 17 System was modified to eliminate an amplification-efficiency reducing primer dimer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Powerplex® 16 in Complex Mixture Analysis of Forensic Samples

We are currently testing the PowerPlex® 16 System in our laboratory in order to use it routinely and change our current management procedure for casework samples, that is to say, the use of two amplifications (Profiler Plus and Profiler) for one sample. So far, our conclusions are that the PowerPlex® 16 System seems to be a good solution for reference samples (database samples or victims/suspec...

متن کامل

PowerPlex® Fusion 6C System: evaluation study for analysis of casework and database samples

AIM To report on the successful analysis of amplicons obtained with PowerPlex® Fusion 6C System, a highly robust 27-plex genotyping kit developed for human identification laboratories, on the Applied Biosystems® 3500 Genetic Analyzer. METHOD We performed characterization and evaluation studies following the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines, exami...

متن کامل

Flood Flow Frequency Model Selection Using L-moment Method in Arid and Semi Arid Regions of Iran

Statistical frequency analysis is the most common procedure for the analysis of flood data at a gauged location thatin first step it is needed to select a model to represent the population. Among them, the central moment has been themost common and widely used, and with the using of computers, the application of the maximum likelihood hasincreased. This research was carried out in order to reco...

متن کامل

بررسی ویژگی‌های آکوستیکی مربوط به کنترل حرکتی گفتار در کودکان لکنتی و غیرلکنتی

Objective Stuttering is a developmental disorder of speech fluency with unknown causes. One of the proposed theories in this field is deficits in speech motor control that is associated with damaged control, timing, and coordination of the speech muscles. Fundamental frequency, fundamental frequency range, intensity, intensity range, and voice onset time are the most important acoustic componen...

متن کامل

Concordance Study between the AmpFlSTR® SGM PlusTM and PowerPlex® 16 System Human Identification Kits in Bangladeshi Population

Short tandem repeat (STR) based DNA typing employing multiplex polymerase chain reaction (PCR) technique is worldwide familiar for forensic investigations and population genetics study [1-3]. SGM PlusTM and PowerPlex®16 system are two popular multiplexes in forensic community and can amplify concurrently 10 and 15 autosomal STR loci respectively with an additional sex determinant amelogenin loc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Forensic science international. Genetics

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 2011