Evaluation of a radiation protection cabin for invasive electrophysiological procedures.

نویسندگان

  • Octavian Dragusin
  • Rukshen Weerasooriya
  • Pierre Jaïs
  • Mélèze Hocini
  • Joris Ector
  • Yoshihide Takahashi
  • Michel Haïssaguerre
  • Hilde Bosmans
  • Hein Heidbüchel
چکیده

AIMS Complex invasive electrophysiological procedures may result in high cumulative operator radiation exposure. Classical protection with lead aprons results in discomfort while radioprotection is still incomplete. This study evaluated the usefulness of a radiation protection cabin (RPC) that completely surrounds the operator. METHODS AND RESULTS The evaluation was performed independently in two electrophysiology laboratories (E1-Leuven, Belgium; E2-Bordeaux, France), comparing operator radiation exposure using the RPC vs. a 0.5 mm lead-equivalent apron (total of 135 procedures). E1 used thermoluminiscent dosimeters (TLDs) placed at 16 positions in and out of the RPC and nine positions in and out of the apron. E2 used more sensitive electronic personal dosimeters (EPD), placed at waist and neck. The sensitivity thresholds of the TLDs and EPDs were 10-20 microSv and 1-1.5 microSv, respectively. All procedures could be performed unimpeded with the RPC. Median TLD dose values outside protected areas were in the range of 57-452 microSv, whereas doses under the apron or inside the RPC were all at the background radiation level, irrespective of procedure and fluoroscopy duration and of radiation energy delivered. In addition, the RPC was protecting the entire body (except the hands), whereas lead apron protection is incomplete. Also with the more sensitive EPDs, the radiation dose within the RPC was at the sensitivity threshold/background level (1.3+/-0.6 microSv). Again, radiation to the head was significantly lower within the RPC (1.9+/-1.2 microSv) than with the apron (102+/-23 microSv, P<0.001). CONCLUSION The use of the RPC allows performing catheter ablation procedures without compromising catheter manipulation, and with negligible radiation exposure for the operator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the annual effective dose to Cath Lab staff in the Afshar Hospital, Yazd and suggesting the radiation protection strategies to better management of occupational dose

Introduction Due to the increasing use of angiography procedures and the higher risk of deterministic and stochastic effects for radiation workers of these sections than other radiological procedures, radiation safety is very important in angiography staff. So, this study aimed to obtain the effective dose of angiography staff and compare them with the standard dose limit and finally outline th...

متن کامل

Evaluation of the Level of Protection in Radiology Departments of Kermanshah, Iran

Introduction Radiation protection is an important safety issue for radiographers and patients. The aim of this study was to assess the observance of radiation protection regulations in radiology departments of Kermanshah University of Medical Sciences, Kermanshah, Iran. Materials and Methods In total, 48 radiographers and 8 radiography rooms were evaluated in three hospitals of Kermanshah, Iran...

متن کامل

Evaluation of the Observance of Radiation Protection Principles in Dentistry Centers in Kermanshah province (West Iran)

Introduction: Radiography plays an important role in the diagnosis of oral and dental disease and one of the most common diagnostic procedures in dentistry. Recent reports have raised concern about the increased use of ionizing radiation in dental imaging and the possibility of cancers. The effective dose of some dental radiographic examinations is high enough, so appropriate ...

متن کامل

Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

متن کامل

Experimental and Numerical Investigation of Air Temperature Distribution inside a Car under Solar Load Condition

In this work both experimental and numerical analysis are carried out to investigate the effect of solar radiation on the cabin air temperature of Maruti Suzuki Celerio car parked for 90 min under solar load condition. The experimental and numerical analysis encompasses on temperature increment of air at various locations ins...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2007