Vertical movement of epithelial basal cells toward the corneal surface during use of extended-wear contact lenses.
نویسندگان
چکیده
PURPOSE To study the effects of extended contact lens wear (EW) on the movement of basal epithelial cells toward the corneal surface. METHODS Rabbits (n = 32) were injected with 5-bromo-2-deoxyuridine (BrdU) to label a group of proliferating basal epithelial cells, and, 24 hours later, one randomly chosen eye was fitted with a low- or medium-oxygen-transmissible (Dk/t) rigid gas permeable (RGP) contact lens, while the other eye served as the control (n = 28). Four rabbits were not fitted with any contact lens. Rabbits were euthanatized at different time points and the corneal epithelium was immunocytochemically stained for BrdU and/or Ki-67 and counterstained with propidium iodide or Syto 59. Corneal flatmount tissues were examined three dimensionally under a laser confocal microscope and the location of each BrdU-labeled cell in the corneal epithelium (basal or suprabasal) was determined. RESULTS Four days after injection of BrdU, both low- (P < 0.001) and medium-Dk/t RGP (P < 0.001) lens groups showed significantly more BrdU-labeled cells in the basal cell layer than in the control eyes. Six days after injection of BrdU, a small percentage of BrdU-labeled cells (<0.5%) were Ki-67 positive. CONCLUSIONS Within 6 days, the majority (80%) of BrdU-labeled basal cells became terminally differentiated and rarely divided secondarily in the central epithelium. Short-term use of low- and medium-Dk/t RGP EW contact lenses slows the normal movement of basal epithelial cells toward the surface in the central cornea. This is consistent with known EW-lens-induced decreases in corneal epithelial basal cell proliferation and surface cell exfoliation. Overall, the data suggest that EW lenses significantly inhibit the normal homeostatic turnover rate of the corneal epithelium.
منابع مشابه
Corneal epithelial permeability during extended wear of disposable contact lenses versus daily wear of soft contact lenses.
AIMS The corneal epithelial permeability during extended wear of disposable contact lenses was compared with that during daily wear of soft contact lenses. The study was performed to verify whether the extended wear of disposable contact lenses would result in a higher permeability value than the daily wear of soft contact lenses. A higher permeability makes the cornea more vulnerable for bacte...
متن کاملExtended contact lens wear enhances Pseudomonas aeruginosa adherence to human corneal epithelium.
Extended wear of soft contact lenses is associated with an increased risk of Pseudomonas aeruginosa infection of the cornea. To assess the role of bacterial adherence in the pathogenesis of these infections, superficial corneal epithelial cells and leukocytes from ten patients who use extended-wear soft lenses and ten control eyes were compared for their propensity to attach P. aeruginosa in vi...
متن کاملExtended wear soft contact lenses induce corneal epithelial changes.
The purpose of this study was to determine the corneal epithelial alterations induced by various types of contact lenses. By employing the specular microscope, the corneal epithelia of 60 patients who had worn contact lenses for more than 1 year were re-examined along with 15 myopic controls. The morphological changes in aphakic patients who changed from extended wear soft to extended wear rigi...
متن کاملShort term wear of high Dk soft contact lenses does not alter corneal epithelial cell size or viability.
BACKGROUND/AIMS Current contact lenses (CLs) when worn on an extended wear basis cause corneal epithelial alterations. The aim of this study was to evaluate changes in corneal epithelial cell morphology and physiology following short term (3 months) wear of highly oxygen permeable CLs and to compare this with disposable CLs. METHODS Subjects were wearers of highly oxygen permeable CLs (n=11, ...
متن کاملThe effect of nonpreserved care solutions on 12 months of daily and extended silicone hydrogel contact lens wear.
PURPOSE To determine the effects of nonpreserved care solutions on human corneal epithelium in long-term daily wear (DW) compared with overnight (extended) wear (EW) of hyper-oxygen-permeable silicone hydrogel contact lenses. METHODS This was a prospective, randomized, double-masked, single-center, parallel treatment group clinical trial (NCT 00344643). One hundred twenty-one patients complet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2003